About: Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The voltammetric behavior and determination of picloram, a member of a pyridine herbicide family, was for the first time investigated on a boron doped diamond film electrode using cyclic and differential pulse voltammetry. The influence of supporting electrolyte and scan rate on the current response of picloram was examined to select the optimum experimental conditions. It was found that picloram provided one well-shaped oxidation peak at very positive potential (+1.5 V vs. Ag/AgCl electrode) in strong acidic medium. At optimized differential pulse voltammetric parameters, the current response of picloram was proportionally linear in the concentration range from 0.5 to 48.07 micromol L-1 and the low limit of detection of 70 nmol L-1 as well as good repeatability (relative standard deviation of 2.6% at 10 micromol L-1 for n = 11) were obtained on unmodified boron-doped diamond film electrode. The proposed method was successfully applied in analysis of environmental (tap and natural water) and biological (human urine) samples spiked with picloram with good accuracy (relative standard deviations less than 5% for all samples, n = 5). By this way, the boron-doped diamond could introduce a green (environmentally acceptable) alternative to mercury electrodes for the monitoring of herbicides.
  • The voltammetric behavior and determination of picloram, a member of a pyridine herbicide family, was for the first time investigated on a boron doped diamond film electrode using cyclic and differential pulse voltammetry. The influence of supporting electrolyte and scan rate on the current response of picloram was examined to select the optimum experimental conditions. It was found that picloram provided one well-shaped oxidation peak at very positive potential (+1.5 V vs. Ag/AgCl electrode) in strong acidic medium. At optimized differential pulse voltammetric parameters, the current response of picloram was proportionally linear in the concentration range from 0.5 to 48.07 micromol L-1 and the low limit of detection of 70 nmol L-1 as well as good repeatability (relative standard deviation of 2.6% at 10 micromol L-1 for n = 11) were obtained on unmodified boron-doped diamond film electrode. The proposed method was successfully applied in analysis of environmental (tap and natural water) and biological (human urine) samples spiked with picloram with good accuracy (relative standard deviations less than 5% for all samples, n = 5). By this way, the boron-doped diamond could introduce a green (environmentally acceptable) alternative to mercury electrodes for the monitoring of herbicides. (en)
Title
  • Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode
  • Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode (en)
skos:prefLabel
  • Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode
  • Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode (en)
skos:notation
  • RIV/00216275:25310/13:39896938!RIV14-MSM-25310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(EE2.3.30.0021)
http://linked.open...iv/cisloPeriodika
  • 30 November 2013
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 115074
http://linked.open...ai/riv/idVysledku
  • RIV/00216275:25310/13:39896938
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Human urine; Environmental sample; Differential pulse voltammetry; Boron-doped diamond film electrode; Picloram (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [0FE97939BCE2]
http://linked.open...i/riv/nazevZdroje
  • Electrochimica Acta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 111
http://linked.open...iv/tvurceVysledku
  • Chýlková, Jaromíra
  • Bandžuchová, Lenka
  • Jana, Svítková
  • Jozef, Sochr
  • Lubomír, Švorc
http://linked.open...ain/vavai/riv/wos
  • 000329531100034
issn
  • 0013-4686
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.electacta.2013.08.071
http://localhost/t...ganizacniJednotka
  • 25310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 38 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software