Attributes | Values |
---|
rdf:type
| |
Description
| - An ion-exchange high-performance liquid chromatography with ultraviolet detection for the determination of creatine in human serum has been developed. The human serum was deproteinized with perchloric acid. For the separation, a cation-exchange column LC-SCX, 250 mm x 4.6 mm, 5 um, was used. The mixture of ethanol and 10mmol l-1 ammonium acetate (15:85, v/v), pH 4.00+/-0.05 was used as a mobile phase. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries of spiked serum samples were between 97.1% and 103.5%. The calibration curve was linear in the whole range tested. The limit of quantification was 2 umol l-1. The preliminary reference ranges of serum creatine in a group of blood donors are 17-89 umol l-1 for women and 21-97 umol l-1 for men.
- An ion-exchange high-performance liquid chromatography with ultraviolet detection for the determination of creatine in human serum has been developed. The human serum was deproteinized with perchloric acid. For the separation, a cation-exchange column LC-SCX, 250 mm x 4.6 mm, 5 um, was used. The mixture of ethanol and 10mmol l-1 ammonium acetate (15:85, v/v), pH 4.00+/-0.05 was used as a mobile phase. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries of spiked serum samples were between 97.1% and 103.5%. The calibration curve was linear in the whole range tested. The limit of quantification was 2 umol l-1. The preliminary reference ranges of serum creatine in a group of blood donors are 17-89 umol l-1 for women and 21-97 umol l-1 for men. (en)
|
Title
| - An assay of creatine in human serum using an HPLC with UV detection
- An assay of creatine in human serum using an HPLC with UV detection (en)
|
skos:prefLabel
| - An assay of creatine in human serum using an HPLC with UV detection
- An assay of creatine in human serum using an HPLC with UV detection (en)
|
skos:notation
| - RIV/00216275:25310/13:39896728!RIV14-MSM-25310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216275:25310/13:39896728
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - reference values; ion-exchange chromatography; creatine (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Kanďár, Roman
- Drábková, Petra
- Štramová, Xenie
|
issn
| |
number of pages
| |