Attributes | Values |
---|
rdf:type
| |
Description
| - In this article, a new typ of non-mercury metal-based electrode, antimony trifluoride-bulk-modified carbon paste electrode (SbF3-CPE) is for the first time reported and examined for electrochemical stripping analysis of selected heavy metal ions at their trace concentration level. In the role of bulk modifier and a source of antimony film generated in state nascenti, SbF3 in a content of 3 % (w/w) in the carbon paste mixture was the ultimate choice. All the important experimental parameters have been optimized by using Cd(II) and Pb(II) as the model ions and employing the square-wave anodic stripping voltammetry (SWASV) as the proper technique. As found out, the SbF3-CPE has exhibited a finely linear response (with R2 = 0.999) in the concentration range of 20-120 mýg L-1 Me(II), while the signal of interest could be reproduced with a relative error of 6.5 % for Cd and 1.2 % for Pb (when n = 7).
- In this article, a new typ of non-mercury metal-based electrode, antimony trifluoride-bulk-modified carbon paste electrode (SbF3-CPE) is for the first time reported and examined for electrochemical stripping analysis of selected heavy metal ions at their trace concentration level. In the role of bulk modifier and a source of antimony film generated in state nascenti, SbF3 in a content of 3 % (w/w) in the carbon paste mixture was the ultimate choice. All the important experimental parameters have been optimized by using Cd(II) and Pb(II) as the model ions and employing the square-wave anodic stripping voltammetry (SWASV) as the proper technique. As found out, the SbF3-CPE has exhibited a finely linear response (with R2 = 0.999) in the concentration range of 20-120 mýg L-1 Me(II), while the signal of interest could be reproduced with a relative error of 6.5 % for Cd and 1.2 % for Pb (when n = 7). (en)
|
Title
| - Antimony Trifluoride-Modified Carbon Paste Electrodes for Electrochemical Stripping Analysis of Selected Heavy Metals
- Antimony Trifluoride-Modified Carbon Paste Electrodes for Electrochemical Stripping Analysis of Selected Heavy Metals (en)
|
skos:prefLabel
| - Antimony Trifluoride-Modified Carbon Paste Electrodes for Electrochemical Stripping Analysis of Selected Heavy Metals
- Antimony Trifluoride-Modified Carbon Paste Electrodes for Electrochemical Stripping Analysis of Selected Heavy Metals (en)
|
skos:notation
| - RIV/00216275:25310/11:39892683!RIV12-MSM-25310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(LC06035), Z(MSM0021627502)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216275:25310/11:39892683
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Cd(II) and Pb(II); Heavy metals; Electrochemical stripping analysis; Carbon paste; Antimony trifluoride; Antimony-modified electrode (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Sensing in Electroanalysis Vol. 6
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Hočevar, Samo
- Stočes, Matěj
- Švancara, Ivan
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |