Attributes | Values |
---|
rdf:type
| |
Description
| - A carbon paste electrode bulk-modified with ammonium tetrafluorobismuthate (BiF4-CPE) was developed and examined in the anodic stripping voltammetric mode for measurement of selected trace heavy metals. The BiF4-CPE has revealed a favorable performance in more acidic solutions (pH 0.5-2.5) in the presence of dissolved oxygen for Cd(II) and Pb(II) as model metal ions at the low ?gL-1 concentration level. In comparison with the bismuth-oxide bulk-modified carbon paste electrode and the other two bismuth film-plated carbona-ceous substrate electrodes examined, the BiF4-CPE proved to be another attractive variant of the environmentally friendly bismuth-based electrodes, particularly convenient for analysis of acidified water samples.
- A carbon paste electrode bulk-modified with ammonium tetrafluorobismuthate (BiF4-CPE) was developed and examined in the anodic stripping voltammetric mode for measurement of selected trace heavy metals. The BiF4-CPE has revealed a favorable performance in more acidic solutions (pH 0.5-2.5) in the presence of dissolved oxygen for Cd(II) and Pb(II) as model metal ions at the low ?gL-1 concentration level. In comparison with the bismuth-oxide bulk-modified carbon paste electrode and the other two bismuth film-plated carbona-ceous substrate electrodes examined, the BiF4-CPE proved to be another attractive variant of the environmentally friendly bismuth-based electrodes, particularly convenient for analysis of acidified water samples. (en)
|
Title
| - A New Type of Bismuth Electrode for Electrochemical Stripping Analysis Based on the Ammonium Tetrafluorobismuthate Bulk-Modified Carbon Paste
- A New Type of Bismuth Electrode for Electrochemical Stripping Analysis Based on the Ammonium Tetrafluorobismuthate Bulk-Modified Carbon Paste (en)
|
skos:prefLabel
| - A New Type of Bismuth Electrode for Electrochemical Stripping Analysis Based on the Ammonium Tetrafluorobismuthate Bulk-Modified Carbon Paste
- A New Type of Bismuth Electrode for Electrochemical Stripping Analysis Based on the Ammonium Tetrafluorobismuthate Bulk-Modified Carbon Paste (en)
|
skos:notation
| - RIV/00216275:25310/10:39882243!RIV11-MSM-25310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(LC06035), Z(MSM0021627502)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216275:25310/10:39882243
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Lead; Cadmium; Anodic stripping voltammetry; Carbon paste electrode; Ammonium tetrafluorobismuthate (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - DE - Spolková republika Německo
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Baldrianová, Lucie
- Tesařová, Eva
- Weidlich, Tomáš
- Švancara, Ivan
- Sopha, Hanna
- Hočevar, Samo B.
- Grincien?, Giedre
|
http://linked.open...ain/vavai/riv/wos
| |
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |