Attributes | Values |
---|
rdf:type
| |
Description
| - The antimony film carbon paste electrode (SbF-CPE) was prepared in situ on the carbon paste substrate electrode as a %22mercury-free%22 electrochemical sensor. Its aptitude for measuring some selected heavy metals has been demonstrated in combination with square-wave anodic stripping voltammetry in non-deaerated model solutions of 0.01 M hydrochloric acid with pH 2. Some important operational parameters, such as deposition potential, deposition time, and concentration of antimony ions were optimized, and the electroanalytical performance of the SbF-CPE was critically compared with both bismuth film carbon paste electrode (BiF-CPE) and mercury film carbon paste electrode (MF-CPE) using Cd(II) and Pb(II) as test metal ions.
- The antimony film carbon paste electrode (SbF-CPE) was prepared in situ on the carbon paste substrate electrode as a %22mercury-free%22 electrochemical sensor. Its aptitude for measuring some selected heavy metals has been demonstrated in combination with square-wave anodic stripping voltammetry in non-deaerated model solutions of 0.01 M hydrochloric acid with pH 2. Some important operational parameters, such as deposition potential, deposition time, and concentration of antimony ions were optimized, and the electroanalytical performance of the SbF-CPE was critically compared with both bismuth film carbon paste electrode (BiF-CPE) and mercury film carbon paste electrode (MF-CPE) using Cd(II) and Pb(II) as test metal ions. (en)
|
Title
| - Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode
- Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode (en)
|
skos:prefLabel
| - Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode
- Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode (en)
|
skos:notation
| - RIV/00216275:25310/09:00008401!RIV10-MSM-25310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(LC06035), Z(MSM0021627502)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216275:25310/09:00008401
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - carbon paste electrode; heavy metals; antimony film; anodic stripping voltammetry (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - GB - Spojené království Velké Británie a Severního Irska
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Baldrianová, Lucie
- Ogorevc, Božidar
- Tesařová, Eva
- Vytřas, Karel
- Švancara, Ivan
- Hočevar, Samo B
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |