About: Direct Determination of Selenium in Human Urine by Electrothermal Atomic Absorption Spectrometry with Deuterium Background Correction     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The elaboration of methodology for the direct determination of Se in urine by ETAAS has been contributed by several authors with the predominant use of Zeeman-background correction (BC) systems which is less affected by spectral effects. A systematic study of several recommended, less commonly applied, and new chemical modifiers, resulted in the optimization of atomization conditions under which accurate analysis became possible also with the use of deuterium lamp BC. Pd (nitrate) + Sr (iodide) + Ag (nitrate) was found to be preferable for the determination of Se in urine. The use of this modifier resulted in the lowest detection limit (3.6 ug l-1) and characteristic mass value (17 pg) and ensured the analytical recoveries close to 100 %. Applying the modifier to standards and samples has enabled the use of matrix-free standard solutions for attaining accurate analysis of diluted urine samples. The accuracy was verified by the use of quality control reference materials and by comparison with RNAA meth
  • The elaboration of methodology for the direct determination of Se in urine by ETAAS has been contributed by several authors with the predominant use of Zeeman-background correction (BC) systems which is less affected by spectral effects. A systematic study of several recommended, less commonly applied, and new chemical modifiers, resulted in the optimization of atomization conditions under which accurate analysis became possible also with the use of deuterium lamp BC. Pd (nitrate) + Sr (iodide) + Ag (nitrate) was found to be preferable for the determination of Se in urine. The use of this modifier resulted in the lowest detection limit (3.6 ug l-1) and characteristic mass value (17 pg) and ensured the analytical recoveries close to 100 %. Applying the modifier to standards and samples has enabled the use of matrix-free standard solutions for attaining accurate analysis of diluted urine samples. The accuracy was verified by the use of quality control reference materials and by comparison with RNAA meth (en)
Title
  • Direct Determination of Selenium in Human Urine by Electrothermal Atomic Absorption Spectrometry with Deuterium Background Correction
  • Direct Determination of Selenium in Human Urine by Electrothermal Atomic Absorption Spectrometry with Deuterium Background Correction (en)
skos:prefLabel
  • Direct Determination of Selenium in Human Urine by Electrothermal Atomic Absorption Spectrometry with Deuterium Background Correction
  • Direct Determination of Selenium in Human Urine by Electrothermal Atomic Absorption Spectrometry with Deuterium Background Correction (en)
skos:notation
  • RIV/00216275:25310/09:00008383!RIV10-MSM-25310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM0021627502)
http://linked.open...iv/cisloPeriodika
  • 12
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 310651
http://linked.open...ai/riv/idVysledku
  • RIV/00216275:25310/09:00008383
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Selenium; ETAAS; Urine analysis; Background correction; Chemical modifiers (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [D200EF881978]
http://linked.open...i/riv/nazevZdroje
  • Scientific Papers of the University of Pardubice, Series A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 15
http://linked.open...iv/tvurceVysledku
  • Husáková, Lenka
  • Šrámková, Jitka
http://linked.open...n/vavai/riv/zamer
issn
  • 1211-5541
number of pages
http://localhost/t...ganizacniJednotka
  • 25310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software