About: Direct Determination of Cd and Pb in Human Urine by GFAAS with Deuterium-lamp Background Correction Using Different Chemical Modifiers     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Several authors have contributed to the elaboration of methodology for direct determination of Cd and Pb in urine by graphite furnace atomic absorption spectrometry (GFAAS). In the proposed approaches, Zeemann background correction systems were predominantly used, without paying much attention to the selection of an appropriate chemical modifier. However, systematic studies on eleven recommended and less commonly used modifiers have resulted in optimization of atomization conditions, so that accurate analysis also with the use of D-2-lamp background correction became possible. This was confirmed by comparative measurements using both background correction systems. For determination of Cd in urine, NH4F has been selected resulting in the lowest limit of detection (LOD): 0.07 mu g L-1. NH4F promotes efficient atomization at low temperatures and suppresses chloride interference effect. Pd + Sr (nitrate) has been selected as the most adequate modifier for determination of Pb. Its presence raised the maxim
  • Several authors have contributed to the elaboration of methodology for direct determination of Cd and Pb in urine by graphite furnace atomic absorption spectrometry (GFAAS). In the proposed approaches, Zeemann background correction systems were predominantly used, without paying much attention to the selection of an appropriate chemical modifier. However, systematic studies on eleven recommended and less commonly used modifiers have resulted in optimization of atomization conditions, so that accurate analysis also with the use of D-2-lamp background correction became possible. This was confirmed by comparative measurements using both background correction systems. For determination of Cd in urine, NH4F has been selected resulting in the lowest limit of detection (LOD): 0.07 mu g L-1. NH4F promotes efficient atomization at low temperatures and suppresses chloride interference effect. Pd + Sr (nitrate) has been selected as the most adequate modifier for determination of Pb. Its presence raised the maxim (en)
  • Přímé stanovení Cd a Pb v moči na instrumentaci vybavené deuteriovou korekcí pozadí (D2) je velice obtížné a proto většina publikovaných prací věnujících se této problematice doporučuje pro stanovení použít Zeemanovu korekci pozadí. Při použití Zeemanovy korekce pozadí pak volba chemického modifikátoru není tak kritickým faktorem dosažení správných výsledků, jak je tomu pro instrumentaci s D2 korekcí. Za účelem možnosti provést přímé stanovení Cd a Pb v moči na instrumentaci s D2 korekcí pozadí bylo testováno jedenáct chemických modifikátorů. Bylo pozorováno, že za optimalizovaných pracovních podmínek, zahrnujících vhodný chemický modifikátor, je správné stanovení obou elementů možné provést i na instrumentaci s D2 korekcí. Pro stanovení Cd v moči byl jako nejlepší chemický modifikátor zvolen NH4F. V jeho přítomnosti bylo dosaženo nejlepší hodnoty detekčního limitu (LOD): 0.07 mu g L-1. Fluorid amonný umožňuje dosažení účinné atomizace při nízkých teplotách a snižuje interferující vliv chloridové matr (cs)
Title
  • Direct Determination of Cd and Pb in Human Urine by GFAAS with Deuterium-lamp Background Correction Using Different Chemical Modifiers
  • Direct Determination of Cd and Pb in Human Urine by GFAAS with Deuterium-lamp Background Correction Using Different Chemical Modifiers (en)
  • Přímé stanovení Cd a Pb v moči metodou GFAAS na instrumentaci vybavené deuteriovou korekcí pozadí a v přítomnosti vybraných chemických modifikátorů (cs)
skos:prefLabel
  • Direct Determination of Cd and Pb in Human Urine by GFAAS with Deuterium-lamp Background Correction Using Different Chemical Modifiers
  • Direct Determination of Cd and Pb in Human Urine by GFAAS with Deuterium-lamp Background Correction Using Different Chemical Modifiers (en)
  • Přímé stanovení Cd a Pb v moči metodou GFAAS na instrumentaci vybavené deuteriovou korekcí pozadí a v přítomnosti vybraných chemických modifikátorů (cs)
skos:notation
  • RIV/00216275:25310/07:00006349!RIV08-MSM-25310___
http://linked.open.../vavai/riv/strany
  • 579-596
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM0021627502)
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 417444
http://linked.open...ai/riv/idVysledku
  • RIV/00216275:25310/07:00006349
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Cadmium; lead; GFAAS; urine; modifiers; background correction (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • PL - Polská republika
http://linked.open...ontrolniKodProRIV
  • [843178D6AA8C]
http://linked.open...i/riv/nazevZdroje
  • Chemia Analityczna
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 52
http://linked.open...iv/tvurceVysledku
  • Husáková, Lenka
  • Černohorský, Tomáš
  • Šrámková, Jitka
  • Bařinová, Martina
http://linked.open...n/vavai/riv/zamer
issn
  • 0009-2223
number of pages
http://localhost/t...ganizacniJednotka
  • 25310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software