About: Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper describes a fast and cheap method for determination of Zn, Ni, Cr, Fe, V, Pb, and Co content in water by the means of wavelength dispersive X-ray fluorescence (WD XRF) spectrometry after preconcentration of the Sample on the ion-exchange filter. The preconcentration was achieved on filters prepared from the Oxin ion-exchanger with 8-hydroxyquinoline functional groups bound to the fibrous cellulose. The sorption conditions for Zr were optimized, which subsequently served as the correction standard. Detection limits (in mug) for maximum volume (500 mL) of the preconcentrated sample were as follows: DLZn = 1.049, DLNi = 0.867, DLCr 0.281, DLFe = 0.512, DLV = 0.549, DLPb = 0.619, DLCo = 0.453. The method of preconcentration is simple and can be realized in mobile laboratories with consecutive laboratory WDXRF analysis.
  • The paper describes a fast and cheap method for determination of Zn, Ni, Cr, Fe, V, Pb, and Co content in water by the means of wavelength dispersive X-ray fluorescence (WD XRF) spectrometry after preconcentration of the Sample on the ion-exchange filter. The preconcentration was achieved on filters prepared from the Oxin ion-exchanger with 8-hydroxyquinoline functional groups bound to the fibrous cellulose. The sorption conditions for Zr were optimized, which subsequently served as the correction standard. Detection limits (in mug) for maximum volume (500 mL) of the preconcentrated sample were as follows: DLZn = 1.049, DLNi = 0.867, DLCr 0.281, DLFe = 0.512, DLV = 0.549, DLPb = 0.619, DLCo = 0.453. The method of preconcentration is simple and can be realized in mobile laboratories with consecutive laboratory WDXRF analysis. (en)
  • The paper describes a fast and cheap method for determination of Zn, Ni, Cr, Fe, V, Pb, and Co content in water by the means of wavelength dispersive X-ray fluorescence (WD XRF) spectrometry after preconcentration of the Sample on the ion-exchange filter. The preconcentration was achieved on filters prepared from the Oxin ion-exchanger with 8-hydroxyquinoline functional groups bound to the fibrous cellulose. The sorption conditions for Zr were optimized, which subsequently served as the correction standard. Detection limits (in mug) for maximum volume (500 mL) of the preconcentrated sample were as follows: DLZn = 1.049, DLNi = 0.867, DLCr 0.281, DLFe = 0.512, DLV = 0.549, DLPb = 0.619, DLCo = 0.453. The method of preconcentration is simple and can be realized in mobile laboratories with consecutive laboratory WDXRF analysis. (cs)
Title
  • Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter
  • Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter (en)
  • Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter (cs)
skos:prefLabel
  • Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter
  • Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter (en)
  • Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter (cs)
skos:notation
  • RIV/00216275:25310/03:00000576!RIV08-MSM-25310___
http://linked.open.../vavai/riv/strany
  • 55-64
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 253100002)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 603366
http://linked.open...ai/riv/idVysledku
  • RIV/00216275:25310/03:00000576
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • X-Ray fluorescence; water; ion-exchange filter; preconcentration techniques (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • PL - Polská republika
http://linked.open...ontrolniKodProRIV
  • [149795F77FCE]
http://linked.open...i/riv/nazevZdroje
  • Chemia Analityczna
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 48
http://linked.open...iv/tvurceVysledku
  • Krejčová, Anna
  • Pouzar, Miloslav
  • Černohorský, Tomáš
http://linked.open...n/vavai/riv/zamer
issn
  • 0009-2223
number of pages
http://localhost/t...ganizacniJednotka
  • 25310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software