About: Capillary electrophoresis with contactless conductometric detection for rapid screening of formate in blood serum after methanol intoxication     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A new method for rapid, direct determination of formate in blood serum samples by capillary electrophoresis with contactless conductometric detection is presented. A selective separation of formate was achieved in approximately 1 min using an electrolyte system comprising 10 mM L-histidine, 15 mM glutamic acid and 30 mu M cetyltrimethylammonium bromide at pH 4.56. The only sample preparation was dilution (1:100) with deionized water. The limit of detection and limit of quantitation was 2.2 mu M and 7.3 mu M, respectively, which corresponds to 0.22 mM and 0.73 mM in undiluted blood serum. The method provides a simple and rapid diagnostic test in suspected methanol intoxication cases. The method has been successfully tested on determination of formate in blood of a patient admitted to the hospital under acute methanol intoxication. The peak concentration of formate detected in the patient blood serum was 12.4 mM, which is 10- to 100-fold higher than the normal values in healthy population.
  • A new method for rapid, direct determination of formate in blood serum samples by capillary electrophoresis with contactless conductometric detection is presented. A selective separation of formate was achieved in approximately 1 min using an electrolyte system comprising 10 mM L-histidine, 15 mM glutamic acid and 30 mu M cetyltrimethylammonium bromide at pH 4.56. The only sample preparation was dilution (1:100) with deionized water. The limit of detection and limit of quantitation was 2.2 mu M and 7.3 mu M, respectively, which corresponds to 0.22 mM and 0.73 mM in undiluted blood serum. The method provides a simple and rapid diagnostic test in suspected methanol intoxication cases. The method has been successfully tested on determination of formate in blood of a patient admitted to the hospital under acute methanol intoxication. The peak concentration of formate detected in the patient blood serum was 12.4 mM, which is 10- to 100-fold higher than the normal values in healthy population. (en)
Title
  • Capillary electrophoresis with contactless conductometric detection for rapid screening of formate in blood serum after methanol intoxication
  • Capillary electrophoresis with contactless conductometric detection for rapid screening of formate in blood serum after methanol intoxication (en)
skos:prefLabel
  • Capillary electrophoresis with contactless conductometric detection for rapid screening of formate in blood serum after methanol intoxication
  • Capillary electrophoresis with contactless conductometric detection for rapid screening of formate in blood serum after methanol intoxication (en)
skos:notation
  • RIV/00216224:14740/13:00068155!RIV14-MSM-14740___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068)
http://linked.open...iv/cisloPeriodika
  • March
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 64228
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14740/13:00068155
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Capillary electrophoresis; Contactless conductivity detection; Formate; Methanol intoxication (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [BC4F915918D4]
http://linked.open...i/riv/nazevZdroje
  • Journal of Chromatography A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 1281
http://linked.open...iv/tvurceVysledku
  • Foret, František
  • Bocek, Robert
  • Kubáň, Petr
http://linked.open...ain/vavai/riv/wos
  • 000315552700019
issn
  • 0021-9673
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.chroma.2013.01.035
http://localhost/t...ganizacniJednotka
  • 14740
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software