About: Influence of analyzed solutions on the plasma pencil discharge     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Herein we show an influence of analyzed water solutions containing elements in acid matrices on both the discharge physical characteristics and the excitation capabilities. It is well known that the presence of acids in solutions depresses measured lines intensities. Acids viscosity can worsen the nebulisation efficiency and the presence of acids in the discharge together with abundant water consume a non-negligible amount of the delivered electrical energy. These phenomena result in a decrease of the intensities of measured atomic emission lines of elements in the introduced solution. The determination of the elements in acid matrices is less sensitive than in pure water solutions. This behaviour is also recognizable in case of the presented plasma pencil. Experiments were realized with three single element containing solutions. The selected elements were Cu, Mg and Zn in the concentration range of 1 – 100 mg l-1 and the contents of 70% nitric acid of 2, 10, 20 and 50 ml per 100 ml flask.
  • Herein we show an influence of analyzed water solutions containing elements in acid matrices on both the discharge physical characteristics and the excitation capabilities. It is well known that the presence of acids in solutions depresses measured lines intensities. Acids viscosity can worsen the nebulisation efficiency and the presence of acids in the discharge together with abundant water consume a non-negligible amount of the delivered electrical energy. These phenomena result in a decrease of the intensities of measured atomic emission lines of elements in the introduced solution. The determination of the elements in acid matrices is less sensitive than in pure water solutions. This behaviour is also recognizable in case of the presented plasma pencil. Experiments were realized with three single element containing solutions. The selected elements were Cu, Mg and Zn in the concentration range of 1 – 100 mg l-1 and the contents of 70% nitric acid of 2, 10, 20 and 50 ml per 100 ml flask. (en)
Title
  • Influence of analyzed solutions on the plasma pencil discharge
  • Influence of analyzed solutions on the plasma pencil discharge (en)
skos:prefLabel
  • Influence of analyzed solutions on the plasma pencil discharge
  • Influence of analyzed solutions on the plasma pencil discharge (en)
skos:notation
  • RIV/00216224:14740/12:00064553!RIV13-MSM-14740___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 141328
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14740/12:00064553
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • plasma pencil; discharge; acid; concentration; intensity (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [ADF4E441E98B]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hrdlička, Aleš
  • Kanický, Viktor
  • Otruba, Vítězslav
  • Slavíček, Pavel
  • Novosád, Lukáš
  • Vaňková, Iva
http://localhost/t...ganizacniJednotka
  • 14740
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software