About: Image acquisition and its automation in fluorescence microscopy     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Fluorescence microscopy is presently the main tool for the investigation of structure and function of cells and their components. Unfortunately, this type of microscopy suffers from low light levels and consequent high noise levels. This poses big challenge for the image acquisition process. The selection of proper hardware and software parts of the whole set-up (microscope, light detector, driving computer) as well as optimization of the imaging conditions are highly non-trivial tasks that require deep understanding of the laws of physics and mutual dependences of a number of phenomena. This chapter brings insight into these laws and dependencies and provides the reader with a number of hints for the selection of appropriate system components as well as for the optimization of their performance. Special attention is paid to automation in fluorescence microscopy that is absolutely indispensable if multi-dimensional data are to be acquired.
  • Fluorescence microscopy is presently the main tool for the investigation of structure and function of cells and their components. Unfortunately, this type of microscopy suffers from low light levels and consequent high noise levels. This poses big challenge for the image acquisition process. The selection of proper hardware and software parts of the whole set-up (microscope, light detector, driving computer) as well as optimization of the imaging conditions are highly non-trivial tasks that require deep understanding of the laws of physics and mutual dependences of a number of phenomena. This chapter brings insight into these laws and dependencies and provides the reader with a number of hints for the selection of appropriate system components as well as for the optimization of their performance. Special attention is paid to automation in fluorescence microscopy that is absolutely indispensable if multi-dimensional data are to be acquired. (en)
Title
  • Image acquisition and its automation in fluorescence microscopy
  • Image acquisition and its automation in fluorescence microscopy (en)
skos:prefLabel
  • Image acquisition and its automation in fluorescence microscopy
  • Image acquisition and its automation in fluorescence microscopy (en)
skos:notation
  • RIV/00216224:14330/05:00013579!RIV11-MSM-14330___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 143300002)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 524217
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14330/05:00013579
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • image acquisition; fluorescence microscopy; automated microscopy; image cytometry; FISH (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [FCADDEF8732B]
http://linked.open...i/riv/mistoVydani
  • Dordrecht
http://linked.open...vEdiceCisloSvazku
  • NATO Science Series
http://linked.open...i/riv/nazevZdroje
  • From cells to proteins: Imaging nature across dimensions
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...v/pocetStranKnihy
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kozubek, Michal
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Springer-Verlag
https://schema.org/isbn
  • 1-4020-3615-9
http://localhost/t...ganizacniJednotka
  • 14330
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software