About: Voltammetric Study of Adenine Complex with Copper on Mercury Electrode     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The determination of adenine (Ade), adenosine (Ado) and hydrolyzed adenosine (h-Ado) in the presence of copper(II) ions is described by cyclic (CV) and elimination voltammetry with linear scan (EVLS) in connection with adsorptive stripping technique. Signals of adenine and copper-adenine complex were measured on a hanging mercury drop electrode (HMDE) in buffered solutions with different pH. The differences in electrochemical behavior of Ad,and Ado were found not only in dependence on the presence of copper ions, scan rate, Ade concentration and pH, but also on the accumulation time and potential where a copper-Ade complex is formed. A deeper evaluation of voltammetric responses was carried out by EVLS. The EVLS function E4 eliminating charging and kinetic current components and conserving the diffusion current component was capable of enhancing the current sensitivity of CV peaks and of detecting electron transfer in adsorbed state.
  • The determination of adenine (Ade), adenosine (Ado) and hydrolyzed adenosine (h-Ado) in the presence of copper(II) ions is described by cyclic (CV) and elimination voltammetry with linear scan (EVLS) in connection with adsorptive stripping technique. Signals of adenine and copper-adenine complex were measured on a hanging mercury drop electrode (HMDE) in buffered solutions with different pH. The differences in electrochemical behavior of Ad,and Ado were found not only in dependence on the presence of copper ions, scan rate, Ade concentration and pH, but also on the accumulation time and potential where a copper-Ade complex is formed. A deeper evaluation of voltammetric responses was carried out by EVLS. The EVLS function E4 eliminating charging and kinetic current components and conserving the diffusion current component was capable of enhancing the current sensitivity of CV peaks and of detecting electron transfer in adsorbed state. (en)
Title
  • Voltammetric Study of Adenine Complex with Copper on Mercury Electrode
  • Voltammetric Study of Adenine Complex with Copper on Mercury Electrode (en)
skos:prefLabel
  • Voltammetric Study of Adenine Complex with Copper on Mercury Electrode
  • Voltammetric Study of Adenine Complex with Copper on Mercury Electrode (en)
skos:notation
  • RIV/00216224:14310/09:00043265!RIV11-MSM-14310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(IAA100040602), P(IAA400040804), P(KAN200040651), P(LC06035), Z(AV0Z50040507), Z(AV0Z50040702), Z(MSM0021622412)
http://linked.open...iv/cisloPeriodika
  • 3-5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 349869
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/09:00043265
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Copper; Copper-adenine complex; Hanging mercury drop electrode; Cyclic voltammetry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [341494A878C0]
http://linked.open...i/riv/nazevZdroje
  • Electroanalysis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 21
http://linked.open...iv/tvurceVysledku
  • Hasoň, Stanislav
  • Kizek, René
  • Trnková, Libuše
  • Jelen, František
  • Kouřilová, Alena
http://linked.open...n/vavai/riv/zamer
issn
  • 1040-0397
number of pages
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software