Attributes | Values |
---|
rdf:type
| |
Description
| - This lecture will describe an instrumentation platform based on universal interface for deposition of CE or microLC eluent on a target of a MALDI mass spectrometer. The deposited fractions of proteins or peptides are analyzed off-line using MALDI mass or tandem mass spectrometry (MS or MS/MS) and native laser-induced fluorescence (LIF) detection or subjected to on-target reactions, such as digestion for protein identification. Another detection mode is inductively coupled plasma optical emission and/or mass spectrometry (ICP OES, resp. MS), nature of which is complementary to soft MALDI MS. For the first time, we proposed MALD for desorption of sample from the target and introduction to ICP. Thus, both information about protein identity and content of elements, such as metals or phosphorus will be available from a single separation record. Initial results of MALD - ICP OES/MS analysis of metal species will be shown to demonstrate the feasibility of the new platform.
- This lecture will describe an instrumentation platform based on universal interface for deposition of CE or microLC eluent on a target of a MALDI mass spectrometer. The deposited fractions of proteins or peptides are analyzed off-line using MALDI mass or tandem mass spectrometry (MS or MS/MS) and native laser-induced fluorescence (LIF) detection or subjected to on-target reactions, such as digestion for protein identification. Another detection mode is inductively coupled plasma optical emission and/or mass spectrometry (ICP OES, resp. MS), nature of which is complementary to soft MALDI MS. For the first time, we proposed MALD for desorption of sample from the target and introduction to ICP. Thus, both information about protein identity and content of elements, such as metals or phosphorus will be available from a single separation record. Initial results of MALD - ICP OES/MS analysis of metal species will be shown to demonstrate the feasibility of the new platform. (en)
|
Title
| - Multidetection platform for microcolumn separation of proteins and peptides (en)
- Multidetection platform for microcolumn separation of proteins and peptides
|
skos:prefLabel
| - Multidetection platform for microcolumn separation of proteins and peptides (en)
- Multidetection platform for microcolumn separation of proteins and peptides
|
skos:notation
| - RIV/00216224:14310/08:00033542!RIV10-MSM-14310___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(LC06035), Z(MSM0021622411), Z(MSM0021622412), Z(MSM0021622415)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216224:14310/08:00033542
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - CE; ICP; MALDI MS; interface; off-line coupling (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...i/riv/kodPristupu
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...n/vavai/riv/nosic
| |
http://linked.open...telVyzkumneZpravy
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| |
http://linked.open...rzeVyzkumneZpravy
| - School of Chemistry Seminar
|
http://linked.open...n/vavai/riv/zamer
| |
http://localhost/t...ganizacniJednotka
| |