About: Double pulse laser ablation and plasma: time resolved spectral measurements     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Most of the studies on double-pulse LIBS have been performed using an intensified CCD (ICCD) detection. Using ICCD, spectral information over wide range can be recorded on each laser pulse. Besides ICCD, also photomultipliers (PMT) can be used to monitor single emission lines. The output of the PMT is a current proportional to the intensity of the incident light. PMTs are not integrating devices as they provide a signal simultaneous in time with the incident light intensity. The combination of ICCD and PMT can be useful to determine both, the spectral and time resolved plasma emission. In this study, we present orthogonal re-heating double pulse experimental system equipped with both ICCD and PMT detection and preliminary measurements of temperatures of plasmas generated on an iron sample.
  • Most of the studies on double-pulse LIBS have been performed using an intensified CCD (ICCD) detection. Using ICCD, spectral information over wide range can be recorded on each laser pulse. Besides ICCD, also photomultipliers (PMT) can be used to monitor single emission lines. The output of the PMT is a current proportional to the intensity of the incident light. PMTs are not integrating devices as they provide a signal simultaneous in time with the incident light intensity. The combination of ICCD and PMT can be useful to determine both, the spectral and time resolved plasma emission. In this study, we present orthogonal re-heating double pulse experimental system equipped with both ICCD and PMT detection and preliminary measurements of temperatures of plasmas generated on an iron sample. (en)
Title
  • Double pulse laser ablation and plasma: time resolved spectral measurements
  • Double pulse laser ablation and plasma: time resolved spectral measurements (en)
skos:prefLabel
  • Double pulse laser ablation and plasma: time resolved spectral measurements
  • Double pulse laser ablation and plasma: time resolved spectral measurements (en)
skos:notation
  • RIV/00216224:14310/08:00027005!RIV10-MSM-14310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ME08002), Z(MSM0021622411)
http://linked.open...iv/cisloPeriodika
  • 16
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 364354
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/08:00027005
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • laser induced breakdown spectroscopy; LIBS; double pulse LIBS; plasma characterization; time resolved measurement; ICCD; photomultiplier (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [A6347FF940B7]
http://linked.open...i/riv/nazevZdroje
  • CHEMICKÉ LISTY
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 102
http://linked.open...iv/tvurceVysledku
  • Kaiser, Jozef
  • Kanický, Viktor
  • Malina, Radomír
  • Novotný, Karel
  • Otruba, Vítězslav
  • Galiová, Michaela
  • Lutzký, Filip
http://linked.open...n/vavai/riv/zamer
issn
  • 0009-2770
number of pages
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software