About: Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In this work, we apply CE-LIF, CE-UV and CE - Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI TOFMS) to investigate derivatization of model peptides and small proteins with rhodamine-based fluorescent reagents, which are compatible with the wavelength of frequency doubled diode pumped Nd:YAG excitation laser (532 nm). While the LIF detection mode is needed for sensitive detection, the MALDI TOFMS analysis can reveal the mass of analytes. Both derivatized and non-derivatized peptides and proteins, the number of fluorescent labels per peptide/proteins and other product of derivatization process can be detected directly from reaction mixtures or after separation. Thus, MALDI TOFMS serves for additional identification of peaks present in CELIF or CEUV electropherograms. For off-line coupling of CE with MALDI MS, subatmospheric deposition interface was used. An examples of final sensitive CELIF separation of derivatized peptides and small proteins are given.
  • In this work, we apply CE-LIF, CE-UV and CE - Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI TOFMS) to investigate derivatization of model peptides and small proteins with rhodamine-based fluorescent reagents, which are compatible with the wavelength of frequency doubled diode pumped Nd:YAG excitation laser (532 nm). While the LIF detection mode is needed for sensitive detection, the MALDI TOFMS analysis can reveal the mass of analytes. Both derivatized and non-derivatized peptides and proteins, the number of fluorescent labels per peptide/proteins and other product of derivatization process can be detected directly from reaction mixtures or after separation. Thus, MALDI TOFMS serves for additional identification of peaks present in CELIF or CEUV electropherograms. For off-line coupling of CE with MALDI MS, subatmospheric deposition interface was used. An examples of final sensitive CELIF separation of derivatized peptides and small proteins are given. (en)
Title
  • Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection
  • Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection (en)
skos:prefLabel
  • Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection
  • Study of Fluorescently Labelled Peptides and Small Proteins Using Capillary Electrophoresis Combined with Laser Induced Fluorescence and MALDI MS Detection (en)
skos:notation
  • RIV/00216224:14310/05:00012704!RIV10-MSM-14310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA203/03/0515), Z(MSM0021622415)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 545226
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/05:00012704
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Derivatization; Fluorescent labelling; Capillary Electrophoresis; MALDI Mass Spectrometry; Peptides and Proteins (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [D3EE0BC0A509]
http://linked.open...v/mistoKonaniAkce
  • Praha, ÚOCHB AVČR
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Collection Symposium Series, Biollogicaly Active Peptides
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Havel, Josef
  • Preisler, Jan
  • Ryvolová, Markéta
  • Táborský, Petr
  • Řehulková, Helena
  • Vrábel, Patrik
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Ústav organické chemie a biochemie AV ČR
https://schema.org/isbn
  • 80-86241-26-2
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software