About: Determination of isoflavones using high-performance liquid chromatography with electrochemical detection (HPLC- ED)     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Stanovení isoflavonů za použití HPLC s elektrochemickou detekcí (cs)
  • A highly sensitive HPLC-ED was developed for the determination of isoflavones. The electrochemical behaviour of daidzein and genistein was studied on a carbon paste electrode by square wave voltammetry. The electrochemical results obtained were used for the development of the HPLC-ED method. The HPLC-ED system used consisted of two solvent delivery pumps and an eight-channel CoulArray electrochemical detector. Isoflavones were separated on an Atlantis dC18 column using a mobile phase consisting of acetonitrile (solvent A) and 0.15 M acetate buffer of pH 5.5 (solvent B) at a flow rate of 0.4 mL/min. The full scan of multi-channel coulometric detection was tested and an optimal potential at 450 mV was chosen for our purposes. The calibration curves were linear (daidzein R2 = 0.9993 and genistein R2 = 0.9987). The relative standard deviation (R.S.D., n = 5) was 2.5 %. The detection limits for daidzein and genistein were 480 and 394 pg/mL (1.8 and 1.5 nM), respectively. Isoflavones extracted from soybean
  • A highly sensitive HPLC-ED was developed for the determination of isoflavones. The electrochemical behaviour of daidzein and genistein was studied on a carbon paste electrode by square wave voltammetry. The electrochemical results obtained were used for the development of the HPLC-ED method. The HPLC-ED system used consisted of two solvent delivery pumps and an eight-channel CoulArray electrochemical detector. Isoflavones were separated on an Atlantis dC18 column using a mobile phase consisting of acetonitrile (solvent A) and 0.15 M acetate buffer of pH 5.5 (solvent B) at a flow rate of 0.4 mL/min. The full scan of multi-channel coulometric detection was tested and an optimal potential at 450 mV was chosen for our purposes. The calibration curves were linear (daidzein R2 = 0.9993 and genistein R2 = 0.9987). The relative standard deviation (R.S.D., n = 5) was 2.5 %. The detection limits for daidzein and genistein were 480 and 394 pg/mL (1.8 and 1.5 nM), respectively. Isoflavones extracted from soybean (en)
Title
  • Stanovení isoflavonů za použití HPLC s elektrochemickou detekcí (cs)
  • Determination of isoflavones using high-performance liquid chromatography with electrochemical detection (HPLC- ED)
  • Determination of isoflavones using high-performance liquid chromatography with electrochemical detection (HPLC- ED) (en)
skos:prefLabel
  • Stanovení isoflavonů za použití HPLC s elektrochemickou detekcí (cs)
  • Determination of isoflavones using high-performance liquid chromatography with electrochemical detection (HPLC- ED)
  • Determination of isoflavones using high-performance liquid chromatography with electrochemical detection (HPLC- ED) (en)
skos:notation
  • RIV/00216224:14310/04:00011236!RIV08-AV0-14310___
http://linked.open.../vavai/riv/strany
  • 433 - 433
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA203/02/0422), P(IAA1163201)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 560082
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/04:00011236
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • HPLC-ED; square wave voltammetry; isoflavones; daidzein; genistein; soybean products (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [C4A5FA69E1C6]
http://linked.open...v/mistoKonaniAkce
  • Thessaloniki, Greece
http://linked.open...i/riv/mistoVydani
  • Thessaloniki, Greece
http://linked.open...i/riv/nazevZdroje
  • Book of Abstracts - 55th Annual Meeting of the ISE
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kizek, René
  • Kubáň, Vlastimil
  • Trnková, Libuše
  • Zehnálek, Josef
  • Klejdus, Bořivoj
  • Petrlová, Jitka
  • Mikelová, Radka
  • Potěšil, David
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • International Society of Electrochemistry
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software