  • Micellar electrokinetic capillary chromatography has been developed as a promising method for the determination of gentiopicroside. The separation conditions have been optimised with respect to the different parameters including SDS concentration, pH and ion strength of the background electrolyte, and temperature of capillary. A buffer consisting of 100 mM SDS in 20 mM sodium dihydrogen phosphate, 20 mM disodium tetraborate pH 8.6 was found to be the most suitable electrolyte for this separation. The applied voltage of 28 kV (positive polarity) and the temperature of capillary 20 oC gave the best separation of secoiridiods. The linear detection range for concentration versus peak area for the assay is from 5 to 500 mg . ml-1 (correlation coefficient 0.9998) with a detection limit of 0.3 mg . ml-1. The inter-day reproducibility of the peak area was 2.5 % and the inter-day reproducibility of the migration time was below 0.16 %. The developed method was successfully used to quantify gentiopicroside in ex
  • Micellar electrokinetic capillary chromatography has been developed as a promising method for the determination of gentiopicroside. The separation conditions have been optimised with respect to the different parameters including SDS concentration, pH and ion strength of the background electrolyte, and temperature of capillary. A buffer consisting of 100 mM SDS in 20 mM sodium dihydrogen phosphate, 20 mM disodium tetraborate pH 8.6 was found to be the most suitable electrolyte for this separation. The applied voltage of 28 kV (positive polarity) and the temperature of capillary 20 oC gave the best separation of secoiridiods. The linear detection range for concentration versus peak area for the assay is from 5 to 500 mg . ml-1 (correlation coefficient 0.9998) with a detection limit of 0.3 mg . ml-1. The inter-day reproducibility of the peak area was 2.5 % and the inter-day reproducibility of the migration time was below 0.16 %. The developed method was successfully used to quantify gentiopicroside in ex (en)
Title
  • Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography
  • Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography (en)
skos:prefLabel
  • Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography
  • Determination of Gentiopicroside in Extracts of Centaurium erythreae and Gentiana lutea by Micellar Electrokinetic Capillary Chromatography (en)
skos:notation
  • RIV/00216224:14310/00:00003302!RIV/2002/GA0/143102/N
http://linked.open.../vavai/riv/strany
  • 1831
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA303/00/D062)
http://linked.open...iv/cisloPeriodika
  • 12
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 708440
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/00:00003302
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • micellar electrokinetic chromatography, gentiopicroside, gentiana, centaurium (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [7917D043AF5E]
http://linked.open...i/riv/nazevZdroje
  • J.Liquid Chromatogr. Rel. Technol.
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...ocetUcastnikuAkce
http://linked.open...nichUcastnikuAkce
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 23
http://linked.open...iv/tvurceVysledku
  • Glatz, Zdeněk
  • Musil, Pavel
  • Pospíšilová, Jiřina
issn
  • 1082-6076
number of pages
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software