About: Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • This paper presents the preparation and application of two new arrangements of silver solid amalgam (AgSA) electrodes for measurements in flow systems - tubular detector based on compact AgSA, and flow-through detector (or reactor) prepared from porous AgSA. Both electrodes were tested for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol, lomustine) compounds under FIA with amperometric detection (Cd2+, Zn2+, 4-nitrophenol) and flow-DPV (lomustine). Furthermore, by combination of the porous reactor with immobilized enzyme and tubular detector the flow amperometric enzymatic biosensor was constructed for determination of glucose in a sample of honey and cholesterol and sarcosine in model samples.
  • This paper presents the preparation and application of two new arrangements of silver solid amalgam (AgSA) electrodes for measurements in flow systems - tubular detector based on compact AgSA, and flow-through detector (or reactor) prepared from porous AgSA. Both electrodes were tested for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol, lomustine) compounds under FIA with amperometric detection (Cd2+, Zn2+, 4-nitrophenol) and flow-DPV (lomustine). Furthermore, by combination of the porous reactor with immobilized enzyme and tubular detector the flow amperometric enzymatic biosensor was constructed for determination of glucose in a sample of honey and cholesterol and sarcosine in model samples. (en)
Title
  • Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
  • Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems (en)
skos:prefLabel
  • Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
  • Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems (en)
skos:notation
  • RIV/00216208:11310/13:10172708!RIV14-GA0-11310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP206/11/1638), P(GAP208/12/1645), P(GBP206/12/G151), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 66787
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11310/13:10172708
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • enzymatic biosensor; silver solid amalgam; amperometric detector; electrochemical detector (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [CCE4066B4C49]
http://linked.open...v/mistoKonaniAkce
  • Jetřichovice, Czech Republic
http://linked.open...i/riv/mistoVydani
  • Ústí nad Labem
http://linked.open...i/riv/nazevZdroje
  • Sborník přednášek mezinárodní odborné konference XXXIII. Moderní Elektrochemické Metody Jetřichovice 20. - 24. května 2013
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Barek, Jiří
  • Josypčuk, Bohdan
  • Josypčuk, Oksana
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Srsenová Lenka - BEST servis Ústí nad Labem
https://schema.org/isbn
  • 978-80-905221-1-4
http://localhost/t...ganizacniJednotka
  • 11310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 38 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software