About: Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of 1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L-1 phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L-1 KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(A (R)) RP-18 E cartridges were used. The extraction yield was (87.0 A +/- 5.8) % (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 mu mol L-1 (2.18-2,180 mu g L-1) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) of the biomarker were 0.013 mu mol L-1 (2.84 mu g L-1) and 0.043 mu mol L-1 (9.39 mu g L-1), respectively, which is sufficient for its determination in the urine of persons exposed to polycyclic aromatic hydrocarbons.
  • A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of 1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L-1 phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L-1 KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(A (R)) RP-18 E cartridges were used. The extraction yield was (87.0 A +/- 5.8) % (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 mu mol L-1 (2.18-2,180 mu g L-1) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) of the biomarker were 0.013 mu mol L-1 (2.84 mu g L-1) and 0.043 mu mol L-1 (9.39 mu g L-1), respectively, which is sufficient for its determination in the urine of persons exposed to polycyclic aromatic hydrocarbons. (en)
Title
  • Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode
  • Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode (en)
skos:prefLabel
  • Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode
  • Determination of 1-hydroxypyrene in human urine by HPLC with electrochemical detection at a boron-doped diamond film electrode (en)
skos:notation
  • RIV/00216208:11310/12:10126406!RIV13-GA0-11310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GBP206/12/G151), P(ME10004), S, Z(MSM0021620857)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 130668
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11310/12:10126406
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Human urine; Solid-phase extraction; Boron-doped diamond film electrode; High-performance liquid chromatography with electrochemical detection; 1-Hydroxypyrene (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [39F066EC3AA8]
http://linked.open...i/riv/nazevZdroje
  • Analytical and Bioanalytical Chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 404
http://linked.open...iv/tvurceVysledku
  • Barek, Jiří
  • Vyskočil, Vlastimil
  • Yosypchuk, Oksana
http://linked.open...ain/vavai/riv/wos
  • 000307251900011
http://linked.open...n/vavai/riv/zamer
issn
  • 1618-2642
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s00216-012-6140-2
http://localhost/t...ganizacniJednotka
  • 11310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 38 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software