About: Rapid Determinations of Saccharides in High-Energy Drinks by Short-Capillary Electrophoresis with Contactless Conductivity Detection     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The methodology for separations of saccharides in standard electrophoretic systems has been transferred to the short-capillary electrophoresis format. The laboratory-designed apparatus used employs a quartz capillary with an internal diameter of 10 mum, a total length of 10 cm and an effective length of 4 cm, in combination with contactless conductivity detection. It has been applied to separations of neutral mono- and disaccharides. The saccharides are separated in the anionic form, in solutions of alkali hydroxides, namely, KOH, NaOH and LiOH. The separation of a model mixture of five saccharides (sucrose, lactose, glucose, fructose and ribose) takes less than one minute, the LOD equaling 15, 35, 19, 17 and 24 mg L-1 and the LOQ equaling 52, 117, 63, 53 and 79 mg L-1 for sucrose, lactose, glucose, fructose and ribose, respectively. The technique developed has been used to determine sucrose, glucose and fructose in high-energy drinks. The separation is finished within less than 50 s, the saccharide contents determined are identical with the declared values within the reliability interval in most cases, the RSD value being mostly less than 2 %. In general, the separation system developed is very convenient for rapid analyses of large sets of similar samples, e.g., in product quality control or environmental monitoring
  • The methodology for separations of saccharides in standard electrophoretic systems has been transferred to the short-capillary electrophoresis format. The laboratory-designed apparatus used employs a quartz capillary with an internal diameter of 10 mum, a total length of 10 cm and an effective length of 4 cm, in combination with contactless conductivity detection. It has been applied to separations of neutral mono- and disaccharides. The saccharides are separated in the anionic form, in solutions of alkali hydroxides, namely, KOH, NaOH and LiOH. The separation of a model mixture of five saccharides (sucrose, lactose, glucose, fructose and ribose) takes less than one minute, the LOD equaling 15, 35, 19, 17 and 24 mg L-1 and the LOQ equaling 52, 117, 63, 53 and 79 mg L-1 for sucrose, lactose, glucose, fructose and ribose, respectively. The technique developed has been used to determine sucrose, glucose and fructose in high-energy drinks. The separation is finished within less than 50 s, the saccharide contents determined are identical with the declared values within the reliability interval in most cases, the RSD value being mostly less than 2 %. In general, the separation system developed is very convenient for rapid analyses of large sets of similar samples, e.g., in product quality control or environmental monitoring (en)
Title
  • Rapid Determinations of Saccharides in High-Energy Drinks by Short-Capillary Electrophoresis with Contactless Conductivity Detection
  • Rapid Determinations of Saccharides in High-Energy Drinks by Short-Capillary Electrophoresis with Contactless Conductivity Detection (en)
skos:prefLabel
  • Rapid Determinations of Saccharides in High-Energy Drinks by Short-Capillary Electrophoresis with Contactless Conductivity Detection
  • Rapid Determinations of Saccharides in High-Energy Drinks by Short-Capillary Electrophoresis with Contactless Conductivity Detection (en)
skos:notation
  • RIV/00216208:11310/12:10123924!RIV13-GA0-11310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP206/10/1231), Z(MSM0021620857)
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 164095
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11310/12:10123924
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Energy drinks; Saccharides; Contactless conductivity detection; Short capillary; Capillary electrophoresis (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [7EAE363A4E69]
http://linked.open...i/riv/nazevZdroje
  • Analytical and Bioanalytical Chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 404
http://linked.open...iv/tvurceVysledku
  • Opekar, František
  • Tůma, Petr
  • Štulík, Karel
  • Vochyánová, Blanka
http://linked.open...ain/vavai/riv/wos
  • 000307957800026
http://linked.open...n/vavai/riv/zamer
issn
  • 1618-2642
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s00216-012-6242-x
http://localhost/t...ganizacniJednotka
  • 11310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 91 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software