About: Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A new method for benzocaine determination employing FIA and HPLC with electrochemical detection on a carbon paste electrode was developed. The optimum conditions for the determination were found. Carrier solution for FIA consisted of B-R buffer pH 4 (80% methanol, v/v) and used flow rate was 1.0 mLmin(-1). Mobile phase for HPLC consisted of B-R buffer pH 4 (75% methanol, v/v) with flow rate 0.4 mLmin(-1). Working potential of +1.2 V was employed. Practical applicability of the methods was tested on the determination of benzocaine in selected pharmaceuticals. The results were in agreement with results obtained using spectrophotometric detection and with one exception also with the content declared by the manufacturer.
  • A new method for benzocaine determination employing FIA and HPLC with electrochemical detection on a carbon paste electrode was developed. The optimum conditions for the determination were found. Carrier solution for FIA consisted of B-R buffer pH 4 (80% methanol, v/v) and used flow rate was 1.0 mLmin(-1). Mobile phase for HPLC consisted of B-R buffer pH 4 (75% methanol, v/v) with flow rate 0.4 mLmin(-1). Working potential of +1.2 V was employed. Practical applicability of the methods was tested on the determination of benzocaine in selected pharmaceuticals. The results were in agreement with results obtained using spectrophotometric detection and with one exception also with the content declared by the manufacturer. (en)
Title
  • Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode
  • Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode (en)
skos:prefLabel
  • Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode
  • Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode (en)
skos:notation
  • RIV/00216208:11310/11:10104905!RIV12-MSM-11310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(LC06035), S, Z(MSM0021620857)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 193808
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11310/11:10104905
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Pharmaceuticals; HPLC; FIA; Carbon paste electrode; Amperometric detection (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [6B1F7EA73D63]
http://linked.open...i/riv/nazevZdroje
  • Electroanalysis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 23
http://linked.open...iv/tvurceVysledku
  • Barek, Jiří
  • Dejmková, Hana
  • Vokálová, Veronika
  • Zima, Jiří
http://linked.open...ain/vavai/riv/wos
  • 000288093400014
http://linked.open...n/vavai/riv/zamer
issn
  • 1040-0397
number of pages
http://bibframe.org/vocab/doi
  • 10.1002/elan.201000646
http://localhost/t...ganizacniJednotka
  • 11310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software