  • A new gradient reversed-phase HPLC method with pre-column derivatization was developed and validated for simultaneous determination of reduced glutathione, carnosine and taurine in new pharmaceutical eye drops. Chromatographic separation was achieved with a fused core analytical column Supelco Ascentis Express C18 (100 mm x 4.6 mm, 2.7 mu m). A 30 mM triethylamine in acetonitrile with 30 mM triethylamine aqueous solution (pH 2.5, adjusted with glacial acetic acid) was used in a gradient elution mode at a flow rate of 0.8 mL min(-1). The column temperature was maintained at 30 degrees C, the injection volume of the derivatized sample was 5 mu L and the detection wavelength was 375 nm. The tested validation parameters included system suitability, accuracy, precision, linearity, LOD, LOQ and sample solution stability. The standard calibration curves showed good linearity with correlation coefficients r > 0.997 for all compounds. The mean percentage recoveries obtained for reduced glutathione, carnosine and taurine were 99.61, 99.38 and 99.43%, respectively. Precision was <2% for retention times and peak areas. The applicability of this method was demonstrated by the analysis of a multicomponent eye drop formulation containing reduced glutathione, carnosine and taurine.
  • A new gradient reversed-phase HPLC method with pre-column derivatization was developed and validated for simultaneous determination of reduced glutathione, carnosine and taurine in new pharmaceutical eye drops. Chromatographic separation was achieved with a fused core analytical column Supelco Ascentis Express C18 (100 mm x 4.6 mm, 2.7 mu m). A 30 mM triethylamine in acetonitrile with 30 mM triethylamine aqueous solution (pH 2.5, adjusted with glacial acetic acid) was used in a gradient elution mode at a flow rate of 0.8 mL min(-1). The column temperature was maintained at 30 degrees C, the injection volume of the derivatized sample was 5 mu L and the detection wavelength was 375 nm. The tested validation parameters included system suitability, accuracy, precision, linearity, LOD, LOQ and sample solution stability. The standard calibration curves showed good linearity with correlation coefficients r > 0.997 for all compounds. The mean percentage recoveries obtained for reduced glutathione, carnosine and taurine were 99.61, 99.38 and 99.43%, respectively. Precision was <2% for retention times and peak areas. The applicability of this method was demonstrated by the analysis of a multicomponent eye drop formulation containing reduced glutathione, carnosine and taurine. (en)
Title
  • A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
  • A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine (en)
skos:prefLabel
  • A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
  • A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine (en)
skos:notation
  • RIV/00216208:11160/14:10282243!RIV15-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.20.0235)
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 773
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/14:10282243
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • separation; validation; plasma; hplc; amino-acids; crystalline lens; mass-spectrometry; electrochemical detection; spectrofluorometric determination; biological samples (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [0A8CABD12A8B]
http://linked.open...i/riv/nazevZdroje
  • Analytical Methods
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 6
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Šatínský, Dalibor
  • Khalikova, Maria A.
  • Novikov, Oleg O.
  • Zhilyakova, Elena T.
  • Zinchenko, Alexandr A.
http://linked.open...ain/vavai/riv/wos
  • 000332129500030
issn
  • 1759-9660
number of pages
http://bibframe.org/vocab/doi
  • 10.1039/c3ay42200c
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software