  • In this work, a simple, economic, and miniaturized flow-based analyzer based on solenoid micropumps is presented. It was applied to determine two parameters of high environmental interest: ammonium and total inorganic carbon (TIC) in natural waters. The method is based on gas diffusion (GD) of CO2 and NH3 through a hydrophobic gas permeable membrane from an acidic or alkaline donor stream, respectively. The analytes are trapped in an acceptor solution, being slightly alkaline for CO2 and slightly acidic for NH3. The analytes are quantified using a homemade stainless steel conductimetric cell. The proposed system required five solenoid micro-pumps, one for each reagent and sample. Two especially made air bubble traps were placed down-stream of the solendoid pumps, which provided the acceptor solutions, by this increasing the method's reproducibility. Values of RSD lower than 1% were obtained. Achieved limits of detection were 0.27 mu mol L-1 for NH4+ and 50 gmol L-1 for TIC. Add-recovery tests were used to prove the trueness of the method and recoveries of 99.5 +/- 7.5% were obtained for both analytes. The proposed system proved to be adequate for monitoring purpose of TIC and NH4+ due to its high sample throughput and repeatability.
  • In this work, a simple, economic, and miniaturized flow-based analyzer based on solenoid micropumps is presented. It was applied to determine two parameters of high environmental interest: ammonium and total inorganic carbon (TIC) in natural waters. The method is based on gas diffusion (GD) of CO2 and NH3 through a hydrophobic gas permeable membrane from an acidic or alkaline donor stream, respectively. The analytes are trapped in an acceptor solution, being slightly alkaline for CO2 and slightly acidic for NH3. The analytes are quantified using a homemade stainless steel conductimetric cell. The proposed system required five solenoid micro-pumps, one for each reagent and sample. Two especially made air bubble traps were placed down-stream of the solendoid pumps, which provided the acceptor solutions, by this increasing the method's reproducibility. Values of RSD lower than 1% were obtained. Achieved limits of detection were 0.27 mu mol L-1 for NH4+ and 50 gmol L-1 for TIC. Add-recovery tests were used to prove the trueness of the method and recoveries of 99.5 +/- 7.5% were obtained for both analytes. The proposed system proved to be adequate for monitoring purpose of TIC and NH4+ due to its high sample throughput and repeatability. (en)
Title
  • A highly reproducible solenoid micropump system for the analysis of total inorganic carbon and ammonium using gas-diffusion with conductimetric detection
  • A highly reproducible solenoid micropump system for the analysis of total inorganic carbon and ammonium using gas-diffusion with conductimetric detection (en)
skos:prefLabel
  • A highly reproducible solenoid micropump system for the analysis of total inorganic carbon and ammonium using gas-diffusion with conductimetric detection
  • A highly reproducible solenoid micropump system for the analysis of total inorganic carbon and ammonium using gas-diffusion with conductimetric detection (en)
skos:notation
  • RIV/00216208:11160/14:10282171!RIV15-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022)
http://linked.open...iv/cisloPeriodika
  • January
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 771
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/14:10282171
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Conductimetric detection; Ammonium; Total inorganic carbon; Gas difussion; Solenoid micropumps; Multipumping flow system (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [670FFBD4D1BC]
http://linked.open...i/riv/nazevZdroje
  • Talanta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 118
http://linked.open...iv/tvurceVysledku
  • Cerda, Víctor
  • Henríquez, Camelia
  • Horstkotte, Burkhard
http://linked.open...ain/vavai/riv/wos
  • 000329553600025
issn
  • 0039-9140
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.talanta.2013.10.005
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software