About: Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A novel approach of head-space single-drop micro-extraction applied to the determination of ethanol in wine is presented. For the first time, the syringe of an automated syringe pump was used as an extraction chamber of adaptable size for a volatile analyte. This approach enabled to apply negative pressure during the enrichment step, which favored the evaporation of the analyte. Placing a slowly spinning magnetic stirring bar inside the syringe, effective syringe cleaning as well as mixing of the sample with buffer solution to suppress the interference of acetic acid was achieved. Ethanol determination was based on the reduction of a single drop of 3 mmol L-1 potassium dichromate dissolved in 8 mol L-1 sulfuric acid. The drop was positioned in the syringe inlet in the head-space above the sample with posterior spectrophotometric quantification. The entire procedure was carried out automatically using a simple sequential injection analyzer system. One analysis required less than 5 min including the washing step. A limit of detection of 0.025% (v/v) of ethanol and an average repeatability of less than 5.0% RSD were achieved. The consumption of dichromate reagent, buffer, and sample per analysis were only 20 mu L, 200 mu L, and 1 mL, respectively. The results of real samples analysis did not differ significantly from those obtained with the references gas chromatography method.
  • A novel approach of head-space single-drop micro-extraction applied to the determination of ethanol in wine is presented. For the first time, the syringe of an automated syringe pump was used as an extraction chamber of adaptable size for a volatile analyte. This approach enabled to apply negative pressure during the enrichment step, which favored the evaporation of the analyte. Placing a slowly spinning magnetic stirring bar inside the syringe, effective syringe cleaning as well as mixing of the sample with buffer solution to suppress the interference of acetic acid was achieved. Ethanol determination was based on the reduction of a single drop of 3 mmol L-1 potassium dichromate dissolved in 8 mol L-1 sulfuric acid. The drop was positioned in the syringe inlet in the head-space above the sample with posterior spectrophotometric quantification. The entire procedure was carried out automatically using a simple sequential injection analyzer system. One analysis required less than 5 min including the washing step. A limit of detection of 0.025% (v/v) of ethanol and an average repeatability of less than 5.0% RSD were achieved. The consumption of dichromate reagent, buffer, and sample per analysis were only 20 mu L, 200 mu L, and 1 mL, respectively. The results of real samples analysis did not differ significantly from those obtained with the references gas chromatography method. (en)
Title
  • Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples
  • Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples (en)
skos:prefLabel
  • Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples
  • Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples (en)
skos:notation
  • RIV/00216208:11160/14:10281833!RIV15-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022), S
http://linked.open...iv/cisloPeriodika
  • May
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 4564
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/14:10281833
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Ethanol; Spectrophotometric detection; Single-drop micro-extraction; Head-space; Sequential injection analysis; In-syringe (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [C2785869245C]
http://linked.open...i/riv/nazevZdroje
  • Analytica Chimica Acta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 828
http://linked.open...iv/tvurceVysledku
  • Sklenářová, Hana
  • Solich, Petr
  • Šrámková, Ivana
  • Horstkotte, Burkhard
http://linked.open...ain/vavai/riv/wos
  • 000336336900007
issn
  • 0003-2670
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.aca.2014.04.031
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 75 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software