About: A rapid HPLC column switching method for sample preparation and determination of beta-carotene in food supplements     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A simple and automated HPLC column-switching method with rapid sample pretreatment has been developed for quantitative determination of beta-carotene in food supplements. Commercially samples of food supplements were dissolved in chloroform with help of saponification with 1 M solution of sodium hydroxide in ultrasound bath. A 20-min sample dissolution/extraction step was necessary before chromatography analysis to transfer beta-carotene from solid state of food supplements preparations (capsules, tablets) to chloroform solution. Sample volume - 3 mu L of chloroform phase was directly injected into the HPLC system. Next on-line sample clean-up was achieved on the pretreatment precolumn Chromolith Guard Cartridge RP-18e (Merck), 10 x 4.6 mm, with a washing mobile phase (methanol:water, 92:8, (v/v)) at a flow rate of 1.5 mL/min. Valve switch to analytical column was set at 2.5 min in a back-flush mode. After column switching to the analytical column Ascentis Express C-18, 30 x 4.6 mm, particle size 2.7 mu m (Sigma Aldrich), the separation and determination of beta-carotene in food supplements was performed using a mobile phase consisting of 100% methanol, column temperature at 60 degrees C and flow rate 1.5 mL/min. The detector was set at 450 nm. Under the optimum chromatographic conditions standard calibration curve was measured with good linearity - correlation coefficient for beta-carotene (r(2) = 0.999014; n = 6) between the peak areas and concentration of beta-carotene 20-200 mu g/mL. Accuracy of the method defined as a mean recovery was in the range 96.66-102.40%. The intraday method precision was satisfactory at three concentration levels 20, 125 and 200 mu g/mL and relative standard deviations were in the range 0.90-1.02%. The chromatography method has shown high sample throughput during column-switching pretreatment process and analysis in one step in short time (6 min) of the whole chromatographic analysis.
  • A simple and automated HPLC column-switching method with rapid sample pretreatment has been developed for quantitative determination of beta-carotene in food supplements. Commercially samples of food supplements were dissolved in chloroform with help of saponification with 1 M solution of sodium hydroxide in ultrasound bath. A 20-min sample dissolution/extraction step was necessary before chromatography analysis to transfer beta-carotene from solid state of food supplements preparations (capsules, tablets) to chloroform solution. Sample volume - 3 mu L of chloroform phase was directly injected into the HPLC system. Next on-line sample clean-up was achieved on the pretreatment precolumn Chromolith Guard Cartridge RP-18e (Merck), 10 x 4.6 mm, with a washing mobile phase (methanol:water, 92:8, (v/v)) at a flow rate of 1.5 mL/min. Valve switch to analytical column was set at 2.5 min in a back-flush mode. After column switching to the analytical column Ascentis Express C-18, 30 x 4.6 mm, particle size 2.7 mu m (Sigma Aldrich), the separation and determination of beta-carotene in food supplements was performed using a mobile phase consisting of 100% methanol, column temperature at 60 degrees C and flow rate 1.5 mL/min. The detector was set at 450 nm. Under the optimum chromatographic conditions standard calibration curve was measured with good linearity - correlation coefficient for beta-carotene (r(2) = 0.999014; n = 6) between the peak areas and concentration of beta-carotene 20-200 mu g/mL. Accuracy of the method defined as a mean recovery was in the range 96.66-102.40%. The intraday method precision was satisfactory at three concentration levels 20, 125 and 200 mu g/mL and relative standard deviations were in the range 0.90-1.02%. The chromatography method has shown high sample throughput during column-switching pretreatment process and analysis in one step in short time (6 min) of the whole chromatographic analysis. (en)
Title
  • A rapid HPLC column switching method for sample preparation and determination of beta-carotene in food supplements
  • A rapid HPLC column switching method for sample preparation and determination of beta-carotene in food supplements (en)
skos:prefLabel
  • A rapid HPLC column switching method for sample preparation and determination of beta-carotene in food supplements
  • A rapid HPLC column switching method for sample preparation and determination of beta-carotene in food supplements (en)
skos:notation
  • RIV/00216208:11160/13:10146037!RIV14-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 58990
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/13:10146037
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Food supplements; HPLC; Column-switching; On-line sample preparation; beta-carotene (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [1280BDB4E5EC]
http://linked.open...i/riv/nazevZdroje
  • Food Chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 141
http://linked.open...iv/tvurceVysledku
  • Solich, Petr
  • Šatínský, Dalibor
  • Brabcová, Ivana
  • Hlaváčková, Markéta
http://linked.open...ain/vavai/riv/wos
  • 000321803500105
issn
  • 0308-8146
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.foodchem.2013.04.063
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software