About: Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Capillary electrophoretic method suitable for the assay of citrus flavonoids (hesperidin, diosmin, and rutin), troxerutin, and ascorbic acid in food supplements and pharmaceutical formulations was devised and validated. The separation was carried out at 25 kV in uncoated fused-silica capillary (50 mu m i.d.; total length, 32 cm (21 cm to detector); and spectrophotometric detection at 280 nm) maintained at 25 A degrees C with 40 mM sodium tetraborate buffer of pH 9.5 containing 25 % (v/v) of methanol as the background electrolyte. The samples were injected hydrodynamically (50 mbar, 6 s). The calibration curves were linear (correlation coefficients r = 0.9994-0.9998) for 0.05-0.50 mg/mL of hesperidin, diosmin, rutin, and troxerutin and 0.10-1.00 mg/mL of ascorbic acid when using cinnamic acid (0.05 mg/mL) as internal standard (IS). The LOQ values (S/N = 10) ranged between 0.02 and 0.04 mg/mL of an analyte. The intra- and interday repeatability of migration times and corrected peak areas was characterized by RSD a parts per thousand currency signaEuro parts per thousand 3.6 %. Single CE analysis of a standard mixture containing all five analytes and the IS took less than 11 min. Accuracy of the method was evaluated by the added/found analyte recovery experiments (recoveries, 95.5-99.8 %). The method was applied to the analysis of five commercially available food supplements and pharmaceuticals.
  • Capillary electrophoretic method suitable for the assay of citrus flavonoids (hesperidin, diosmin, and rutin), troxerutin, and ascorbic acid in food supplements and pharmaceutical formulations was devised and validated. The separation was carried out at 25 kV in uncoated fused-silica capillary (50 mu m i.d.; total length, 32 cm (21 cm to detector); and spectrophotometric detection at 280 nm) maintained at 25 A degrees C with 40 mM sodium tetraborate buffer of pH 9.5 containing 25 % (v/v) of methanol as the background electrolyte. The samples were injected hydrodynamically (50 mbar, 6 s). The calibration curves were linear (correlation coefficients r = 0.9994-0.9998) for 0.05-0.50 mg/mL of hesperidin, diosmin, rutin, and troxerutin and 0.10-1.00 mg/mL of ascorbic acid when using cinnamic acid (0.05 mg/mL) as internal standard (IS). The LOQ values (S/N = 10) ranged between 0.02 and 0.04 mg/mL of an analyte. The intra- and interday repeatability of migration times and corrected peak areas was characterized by RSD a parts per thousand currency signaEuro parts per thousand 3.6 %. Single CE analysis of a standard mixture containing all five analytes and the IS took less than 11 min. Accuracy of the method was evaluated by the added/found analyte recovery experiments (recoveries, 95.5-99.8 %). The method was applied to the analysis of five commercially available food supplements and pharmaceuticals. (en)
Title
  • Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis
  • Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis (en)
skos:prefLabel
  • Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis
  • Assay of Citrus Flavonoids, Troxerutin, and Ascorbic Acid in Food Supplements and Pharmaceuticals by Capillary Zone Electrophoresis (en)
skos:notation
  • RIV/00216208:11160/13:10145776!RIV14-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S
http://linked.open...iv/cisloPeriodika
  • 6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 62212
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/13:10145776
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Troxerutin; Nutraceuticals; Pharmaceuticals; Citrus flavonoids; Capillary zone electrophoresis; Ascorbic acid (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [5129D6002B5F]
http://linked.open...i/riv/nazevZdroje
  • Food Analytical Methods
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 6
http://linked.open...iv/tvurceVysledku
  • Pospíšilová, Marie
  • Polášek, Miroslav
  • Široká, Jitka
  • Martincová, Andrea
http://linked.open...ain/vavai/riv/wos
  • 000326691300009
issn
  • 1936-9751
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s12161-013-9573-0
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 84 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software