About: A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A monolithic flow conduit was especially designed and coupled to a multisyringe unit (MSFIA) in order to develop a kinetic analytical method. The new device, denoted CHIP, integrates different functions in a reduced size including confluent mixing, reaction coil, and thermostating, which allowed minimizing the dimensions of the entire analyzer system. The CHIP-MSFIA was satisfactorily applied to the determination of iodide using the Sandell-Kolthoff reaction. The resulting system allows fast, simple and automatic analysis in seawater samples and a pharmaceutical preparation. By the use of an additional syringe, reagent blank, sample blank, unspecific interferences, and sample analyte concentration was evaluated by simply changing the mode of operation. The instrumentation and analytical procedures were optimized in respect of sensitivity. A limit of detection of 4.7 mu g L-1 and linear working range of 4.3-70 mu g L-1 were achieved. Two new modes of air bubble elimination were developed and employed in this work, leading to improved reproducibility (RSD %= 1.5%) and method robustness. The accuracy of analysis for seawater samples was evaluated by an Add-Recovery test obtaining recoveries between 97 and 106%. For the quantification of iodide in the pharmaceutical sample, standard addition calibration was required. No significant differences between the found and the certified value were found. The entire analytical procedure lasted about 150 s enabling a measuring frequency of 23 h(-1).
  • A monolithic flow conduit was especially designed and coupled to a multisyringe unit (MSFIA) in order to develop a kinetic analytical method. The new device, denoted CHIP, integrates different functions in a reduced size including confluent mixing, reaction coil, and thermostating, which allowed minimizing the dimensions of the entire analyzer system. The CHIP-MSFIA was satisfactorily applied to the determination of iodide using the Sandell-Kolthoff reaction. The resulting system allows fast, simple and automatic analysis in seawater samples and a pharmaceutical preparation. By the use of an additional syringe, reagent blank, sample blank, unspecific interferences, and sample analyte concentration was evaluated by simply changing the mode of operation. The instrumentation and analytical procedures were optimized in respect of sensitivity. A limit of detection of 4.7 mu g L-1 and linear working range of 4.3-70 mu g L-1 were achieved. Two new modes of air bubble elimination were developed and employed in this work, leading to improved reproducibility (RSD %= 1.5%) and method robustness. The accuracy of analysis for seawater samples was evaluated by an Add-Recovery test obtaining recoveries between 97 and 106%. For the quantification of iodide in the pharmaceutical sample, standard addition calibration was required. No significant differences between the found and the certified value were found. The entire analytical procedure lasted about 150 s enabling a measuring frequency of 23 h(-1). (en)
Title
  • A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples
  • A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples (en)
skos:prefLabel
  • A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples
  • A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples (en)
skos:notation
  • RIV/00216208:11160/13:10145758!RIV14-MSM-11160___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE2.3.30.0022)
http://linked.open...iv/cisloPeriodika
  • April
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
  • Horstkotte, Burkhard
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 58744
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11160/13:10145758
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Multisyringe flow injection analysis; Flow conduit; Kinetic determination; Air-bubble removal; Iodide (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [8540D7AAA43F]
http://linked.open...i/riv/nazevZdroje
  • Talanta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 108
http://linked.open...iv/tvurceVysledku
  • Abouhiat, Fatima Zohra
  • Cerda, Víctor
  • El Yousfi, Farida
  • Henríquez, Camelia
  • Horstkotte, Burkhard
http://linked.open...ain/vavai/riv/wos
  • 000319088900014
issn
  • 0039-9140
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.talanta.2013.02.072
http://localhost/t...ganizacniJednotka
  • 11160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software