Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - A simple on-line method for simultaneous determination of some oestrogens including oestriol (E3), norethisterone (NORE), ethynylestradiol (EE2), D-norgestrel (NORG) and bisphenol A (BPA), in environmental liquid samples was developed by coupling in-tube solid phase microextraction (in-tube SPME) to high-performance liquid chromatography with diode array (DAD) and fluorescence (FLD) detectors. Two capillary chromatographic columns (Supel-Q (TM) and Carboxen (TM) 1006 porous layer open tubular) were selected to develop this method. To achieve optimum extraction performance, several parameters were investigated including number of draw/eject cycles and the sample volume for each of the columns. Reproducibility was satisfactory for inter-and intra-day precision, yielding % RSDs of less than 10% and 7.6%, respectively. Limits of detection (LODs) and quantification (LOQs) for the proposed method using a DAD detector were achieved in the ranges of 0.04-0.63 ng mL(-1) and 0.12-1.9 ng mL(-1), depending of the capillary column used. Fluorescence detection improved these parameters for E3, BPA and EE2, obtaining LODs of 0.005-0.03 ng mL(-1) and LOQs of 0.015-0.08 ng mL(-1) using Supel-Q and LODs of 0.01-0.015 ng mL(-1) and LOQs of 0.025-0.04 ng mL(-1) using Carboxen. The proposed method was successfully applied to spiked environmental waters obtaining recoveries greater than 80%.
- A simple on-line method for simultaneous determination of some oestrogens including oestriol (E3), norethisterone (NORE), ethynylestradiol (EE2), D-norgestrel (NORG) and bisphenol A (BPA), in environmental liquid samples was developed by coupling in-tube solid phase microextraction (in-tube SPME) to high-performance liquid chromatography with diode array (DAD) and fluorescence (FLD) detectors. Two capillary chromatographic columns (Supel-Q (TM) and Carboxen (TM) 1006 porous layer open tubular) were selected to develop this method. To achieve optimum extraction performance, several parameters were investigated including number of draw/eject cycles and the sample volume for each of the columns. Reproducibility was satisfactory for inter-and intra-day precision, yielding % RSDs of less than 10% and 7.6%, respectively. Limits of detection (LODs) and quantification (LOQs) for the proposed method using a DAD detector were achieved in the ranges of 0.04-0.63 ng mL(-1) and 0.12-1.9 ng mL(-1), depending of the capillary column used. Fluorescence detection improved these parameters for E3, BPA and EE2, obtaining LODs of 0.005-0.03 ng mL(-1) and LOQs of 0.015-0.08 ng mL(-1) using Supel-Q and LODs of 0.01-0.015 ng mL(-1) and LOQs of 0.025-0.04 ng mL(-1) using Carboxen. The proposed method was successfully applied to spiked environmental waters obtaining recoveries greater than 80%. (en)
|
Title
| - Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns
- Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns (en)
|
skos:prefLabel
| - Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns
- Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns (en)
|
skos:notation
| - RIV/00216208:11160/12:10124750!RIV13-AV0-11160___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216208:11160/12:10124750
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - liquid chromatography; effluent of wastewater treatment plant; sea water; in-tube SPME; endocrine disruptor chemicals (EDCs); oestrogens (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - CH - Švýcarská konfederace
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - International Journal of Environmental Analytical Chemistry
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Solich, Petr
- Aufartová, Jana
- Santana-Rodríguez, José Juan
- Sosa-Ferrera, Zoraida
- Torres-Padrón, María Esther
|
http://linked.open...ain/vavai/riv/wos
| |
issn
| |
number of pages
| |
http://bibframe.org/vocab/doi
| - 10.1080/03067319.2011.585714
|
http://localhost/t...ganizacniJednotka
| |