About: Noninvasive assessment of carotid-femoral pulse wave velocity: the influence of body side and body contours     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Background: Recently, an expert group advised to measure carotid-femoral (cf) pulse wave velocity (PWV) on the right side of the body, and to use a sliding caliper when tape measure distance cannot be obtained in a straight line. The present study investigates the evidence for this advice by comparing the real travelled cf path lengths (RTPLs) at both body sides and comparing the straight distance (as can be obtained with a sliding caliper) with the tape measure distance. Methods: RTPLs were measured with MRI in 98 individuals (49 men, age 21-76 years). Path lengths from the aortic arch to the carotid (AA-CA) and femoral (AA-FA) sites were determined. RTPL was calculated as (AA-FA) - (AA-CA) and compared between both sides. RTPLs were compared with 80% of the direct cf distance using a tape measure and the straight cf distance obtained from MRI images. Results: RTPL was slightly longer [11mm (12), P < 0.001] at the right side. The 80%-rule overestimated RTPLs with 0.5% at the right and 2.7% at the left side. Straight MRI distance tended (P = 0.09) to perform slightly better than tape measure distance. Conclusion: The travelled cf path is slightly longer at the right than at the left body side and the straight MRI distance tends to perform better than tape measure distance. The present study supports the advice of the expert consensus group to measure cf-PWV at the right body side using a sliding caliper when tape measure distance cannot be obtained in a straight line.
  • Background: Recently, an expert group advised to measure carotid-femoral (cf) pulse wave velocity (PWV) on the right side of the body, and to use a sliding caliper when tape measure distance cannot be obtained in a straight line. The present study investigates the evidence for this advice by comparing the real travelled cf path lengths (RTPLs) at both body sides and comparing the straight distance (as can be obtained with a sliding caliper) with the tape measure distance. Methods: RTPLs were measured with MRI in 98 individuals (49 men, age 21-76 years). Path lengths from the aortic arch to the carotid (AA-CA) and femoral (AA-FA) sites were determined. RTPL was calculated as (AA-FA) - (AA-CA) and compared between both sides. RTPLs were compared with 80% of the direct cf distance using a tape measure and the straight cf distance obtained from MRI images. Results: RTPL was slightly longer [11mm (12), P < 0.001] at the right side. The 80%-rule overestimated RTPLs with 0.5% at the right and 2.7% at the left side. Straight MRI distance tended (P = 0.09) to perform slightly better than tape measure distance. Conclusion: The travelled cf path is slightly longer at the right than at the left body side and the straight MRI distance tends to perform better than tape measure distance. The present study supports the advice of the expert consensus group to measure cf-PWV at the right body side using a sliding caliper when tape measure distance cannot be obtained in a straight line. (en)
Title
  • Noninvasive assessment of carotid-femoral pulse wave velocity: the influence of body side and body contours
  • Noninvasive assessment of carotid-femoral pulse wave velocity: the influence of body side and body contours (en)
skos:prefLabel
  • Noninvasive assessment of carotid-femoral pulse wave velocity: the influence of body side and body contours
  • Noninvasive assessment of carotid-femoral pulse wave velocity: the influence of body side and body contours (en)
skos:notation
  • RIV/00216208:11140/13:10140192!RIV14-MSM-11140___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 91942
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11140/13:10140192
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • distance standardization; carotid-femoral pulse wave velocity; body side; body contours; arterial stiffness (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [B70C47D8AAC1]
http://linked.open...i/riv/nazevZdroje
  • Journal of Hypertension
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 31
http://linked.open...iv/tvurceVysledku
  • Filipovský, Jan
  • Segers, Patrick
  • Van Bortel, Luc M.
  • Azermai, Majda
  • Bossuyt, Jelle
  • De Backer, Tine L. M.
  • Devos, Daniel G.
  • Heyse, Catherine
  • Van De Velde, Sandrien
  • Vermeersch, Sebastian J.
http://linked.open...ain/vavai/riv/wos
  • 000317115000016
issn
  • 0263-6352
number of pages
http://bibframe.org/vocab/doi
  • 10.1097/HJH.0b013e328360275d
http://localhost/t...ganizacniJednotka
  • 11140
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software