About: A prospective randomised multicentre clinical comparison of a minimised perfusion circuit versus conventional cardiopulmonary bypass     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Objective: Minimised perfusion circuits (MPCs) are expected to reduce the side effects of conventional cardiopulmonary bypass (CCPB); however, conclusive data from sufficiently powered clinical trials are lacking. The purpose of this study was to evaluate the safety and efficacy of the ROCsafeRX (TM) minimised perfusion circuit. Methods: A randomised, controlled, multicentre clinical trial comparing both perfusion circuits in patients subjected to elective coronary artery bypass and/or aortic valve replacement is described. The primary end points of safety, defined as procedure success without device-related complications, and secondary end point of efficacy, including reduction of transfusion requirement and incidence of atrial fibrillation, are analysed. Results: To date, 291 patients have been enrolled and randomised (146 MPC vs 145 CCPB). With the exception of a significantly higher male population in the MPC group (83.6% vs 71.0%, p = 0.01), both groups were well matched for demographic data and type of surgery. There were no device-related complications but a hard-shell reservoir had to be integrated in one MPC because of a tear in the right atrium that was managed uneventfully. Total transfusion requirement (329 +/- 599 ml vs 783 +/- 1638 ml, p {= 0.001) and erythrocyte transfusion (181 +/- 341 ml vs 434 +/- 798 ml, p {= 0.001) were significantly reduced in the MPC group. The incidence of atrial fibrillation was significantly lower in the MPC group (7.1% vs 19.5%, p {= 0.01), while freedom of major adverse events showed no significant difference. Conclusions: Lack of device-related complications combined with a significant reduction in postoperative atrial fibrillation and transfusion requirements have shown the ROCsafeRX (TM) MPC to be both safe and efficient for large-scale use in cardiac patients. Additional data are expected to confirm these initial findings. (C) 2010 European Association for Cardio-Thoracic Surgery.
  • Objective: Minimised perfusion circuits (MPCs) are expected to reduce the side effects of conventional cardiopulmonary bypass (CCPB); however, conclusive data from sufficiently powered clinical trials are lacking. The purpose of this study was to evaluate the safety and efficacy of the ROCsafeRX (TM) minimised perfusion circuit. Methods: A randomised, controlled, multicentre clinical trial comparing both perfusion circuits in patients subjected to elective coronary artery bypass and/or aortic valve replacement is described. The primary end points of safety, defined as procedure success without device-related complications, and secondary end point of efficacy, including reduction of transfusion requirement and incidence of atrial fibrillation, are analysed. Results: To date, 291 patients have been enrolled and randomised (146 MPC vs 145 CCPB). With the exception of a significantly higher male population in the MPC group (83.6% vs 71.0%, p = 0.01), both groups were well matched for demographic data and type of surgery. There were no device-related complications but a hard-shell reservoir had to be integrated in one MPC because of a tear in the right atrium that was managed uneventfully. Total transfusion requirement (329 +/- 599 ml vs 783 +/- 1638 ml, p {= 0.001) and erythrocyte transfusion (181 +/- 341 ml vs 434 +/- 798 ml, p {= 0.001) were significantly reduced in the MPC group. The incidence of atrial fibrillation was significantly lower in the MPC group (7.1% vs 19.5%, p {= 0.01), while freedom of major adverse events showed no significant difference. Conclusions: Lack of device-related complications combined with a significant reduction in postoperative atrial fibrillation and transfusion requirements have shown the ROCsafeRX (TM) MPC to be both safe and efficient for large-scale use in cardiac patients. Additional data are expected to confirm these initial findings. (C) 2010 European Association for Cardio-Thoracic Surgery. (en)
Title
  • A prospective randomised multicentre clinical comparison of a minimised perfusion circuit versus conventional cardiopulmonary bypass
  • A prospective randomised multicentre clinical comparison of a minimised perfusion circuit versus conventional cardiopulmonary bypass (en)
skos:prefLabel
  • A prospective randomised multicentre clinical comparison of a minimised perfusion circuit versus conventional cardiopulmonary bypass
  • A prospective randomised multicentre clinical comparison of a minimised perfusion circuit versus conventional cardiopulmonary bypass (en)
skos:notation
  • RIV/00216208:11140/10:10282033!RIV15-MSM-11140___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • V
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 244888
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11140/10:10282033
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Transfusion requirements; Aortic valve replacement; Coronary artery bypass; Minimised perfusion circuits (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [9A0FA27AA4F6]
http://linked.open...i/riv/nazevZdroje
  • European Journal of Cardio-thoracic Surgery
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 38
http://linked.open...iv/tvurceVysledku
  • Hájek, Tomáš
  • Sabol, František
  • Škorpil, Jiří
  • Böning, Andreas
  • El-Essawi, Aschraf
  • Harringer, Wolfgang
  • Hausmann, Harald
  • Ostrovsky, Yuri
http://linked.open...ain/vavai/riv/wos
  • 000279744400017
issn
  • 1010-7940
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.ejcts.2010.01.035
http://localhost/t...ganizacniJednotka
  • 11140
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software