  • This study was designed to assess the biomechanical interactions between the coronary artery wall and intracoronary stents following implantation in vitro. Balloon expandable stent was deployed in vitro into the sample of the left anterior descending coronary artery of a 67 years old female with multiple atherosclerotic lesions. The stent was selected to match approximately the internal diameter of the healthy segment of the target artery. The stent implantation procedure was recorded with CCD camera. Digital images were subsequently processed with the edge detector based on Canny algorithm. Obtained coordinates of the surface contours were used in the deformation analysis. For the sake of simplicity the deformation was considered as the ratio between the distances of deformed and reference contour points at the same longitudinal position. We found that the stent expansion induced significant over-stretching of the external coronary artery. We have concluded that optical tracking of the external surface of the artery during the stent deployment provides sufficiently accurate deformation analysis potentially useful in the assessment of biomechanical interactions during intracoronary stenting.
  • This study was designed to assess the biomechanical interactions between the coronary artery wall and intracoronary stents following implantation in vitro. Balloon expandable stent was deployed in vitro into the sample of the left anterior descending coronary artery of a 67 years old female with multiple atherosclerotic lesions. The stent was selected to match approximately the internal diameter of the healthy segment of the target artery. The stent implantation procedure was recorded with CCD camera. Digital images were subsequently processed with the edge detector based on Canny algorithm. Obtained coordinates of the surface contours were used in the deformation analysis. For the sake of simplicity the deformation was considered as the ratio between the distances of deformed and reference contour points at the same longitudinal position. We found that the stent expansion induced significant over-stretching of the external coronary artery. We have concluded that optical tracking of the external surface of the artery during the stent deployment provides sufficiently accurate deformation analysis potentially useful in the assessment of biomechanical interactions during intracoronary stenting. (en)
Title
  • In vitro coronary stent implantation: Vessel wall-stent interaction
  • In vitro coronary stent implantation: Vessel wall-stent interaction (en)
skos:prefLabel
  • In vitro coronary stent implantation: Vessel wall-stent interaction
  • In vitro coronary stent implantation: Vessel wall-stent interaction (en)
skos:notation
  • RIV/00216208:11120/12:00003227!RIV15-GA0-11120___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA106/08/0557)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 141039
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11120/12:00003227
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • stent-artery interaction; PCI; over-stretching; coronary stent; edge detection (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [D274221B1526]
http://linked.open...v/mistoKonaniAkce
  • Budapest
http://linked.open...i/riv/mistoVydani
  • Heidelberg
http://linked.open...i/riv/nazevZdroje
  • 5th European Conference of the International Federation for Medical and Biological Engineering
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Adámek, Tomáš
http://linked.open...vavai/riv/typAkce
http://linked.open...ain/vavai/riv/wos
  • 000310938200207
http://linked.open.../riv/zahajeniAkce
issn
  • 1680-0737
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/978-3-642-23508-5_207
http://purl.org/ne...btex#hasPublisher
  • Springer Medizin Verlag
https://schema.org/isbn
  • 978-3-642-23508-5
http://localhost/t...ganizacniJednotka
  • 11120
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software