About: Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • To determine the relationship between the degree of tricuspid regurgitation (TR) and accuracy of cardiac output measurement by thermodilution in mechanically ventilated patients. We examined 27 patients (not undergoing cardiac surgery): 8 with no or 1st degree TR, 9 with 2nd degree, and 10 with 3rd degree TR. All patients were measured twice using simultaneously transesophageal echocardiography and pulmonary artery catheter for cardiac output. Continuous Doppler measurements were taken in the left ventricular outflow tract at the level of the aortic valve. Cardiac output was calculated by multiplying the velocity-time integral by aortic valve area and heart rate. Simultaneous pulmonary artery catheter measurements were taken averaging the results of the three 10-cc boluses of iced saline. The difference between the methods was 0.5+/-1.1 l/min (mean +/- 2 SD) in patients with no or 1st degree TR (r=0.96), 0.8 2.0 l/min in those with 2nd degree TR (r=0.92), and 1.9+/-2.3 l/min in those with 3rd degree T
  • To determine the relationship between the degree of tricuspid regurgitation (TR) and accuracy of cardiac output measurement by thermodilution in mechanically ventilated patients. We examined 27 patients (not undergoing cardiac surgery): 8 with no or 1st degree TR, 9 with 2nd degree, and 10 with 3rd degree TR. All patients were measured twice using simultaneously transesophageal echocardiography and pulmonary artery catheter for cardiac output. Continuous Doppler measurements were taken in the left ventricular outflow tract at the level of the aortic valve. Cardiac output was calculated by multiplying the velocity-time integral by aortic valve area and heart rate. Simultaneous pulmonary artery catheter measurements were taken averaging the results of the three 10-cc boluses of iced saline. The difference between the methods was 0.5+/-1.1 l/min (mean +/- 2 SD) in patients with no or 1st degree TR (r=0.96), 0.8 2.0 l/min in those with 2nd degree TR (r=0.92), and 1.9+/-2.3 l/min in those with 3rd degree T (en)
Title
  • Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution
  • Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution (en)
skos:prefLabel
  • Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution
  • Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution (en)
skos:notation
  • RIV/00216208:11120/02:00003688!RIV12-MSM-11120___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • V
http://linked.open...iv/cisloPeriodika
  • 8
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 644351
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11120/02:00003688
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • tricuspid regurgitation; cardiac output; echocardiography; Doppler ultrasonography; pulmonary artery catheter; thermodilution (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • BE - Belgické království
http://linked.open...ontrolniKodProRIV
  • [95D2B2CA8A3D]
http://linked.open...i/riv/nazevZdroje
  • Intensive Care Medicine
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 28
http://linked.open...iv/tvurceVysledku
  • Balík, Martin
  • Pachl, Jan
http://linked.open...ain/vavai/riv/wos
  • 000180739200019
issn
  • 0342-4642
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s00134-002-1352-0
http://localhost/t...ganizacniJednotka
  • 11120
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software