About: A simple Fourier filter for suppression of the missing wedge ray artefacts in single-axis electron tomographic reconstructions     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The limited specimen tilting range that is typically available in electron tomography gives rise to a region in the Fourier space of the reconstructed object where experimental data are unavailable - the missing wedge. Since this region is sharply delimited from the area of available data, the reconstructed signal is typically hampered by convolution with its impulse response, which gives rise to the well-known missing wedge artefacts in 3D reconstructions. Despite the recent progress in the field of reconstruction and regularization techniques, the missing wedge artefacts remain untreated in most current reconstruction workflows in structural biology. Therefore we have designed a simple Fourier angular filter that effectively suppresses the ray artefacts in the single-axis tilting projection acquisition scheme, making single-axis tomographic reconstructions easier to interpret in particular at low signal-to-noise ratio in acquired projections. The proposed filter can be easily incorporated into current electron tomographic reconstruction schemes.
  • The limited specimen tilting range that is typically available in electron tomography gives rise to a region in the Fourier space of the reconstructed object where experimental data are unavailable - the missing wedge. Since this region is sharply delimited from the area of available data, the reconstructed signal is typically hampered by convolution with its impulse response, which gives rise to the well-known missing wedge artefacts in 3D reconstructions. Despite the recent progress in the field of reconstruction and regularization techniques, the missing wedge artefacts remain untreated in most current reconstruction workflows in structural biology. Therefore we have designed a simple Fourier angular filter that effectively suppresses the ray artefacts in the single-axis tilting projection acquisition scheme, making single-axis tomographic reconstructions easier to interpret in particular at low signal-to-noise ratio in acquired projections. The proposed filter can be easily incorporated into current electron tomographic reconstruction schemes. (en)
Title
  • A simple Fourier filter for suppression of the missing wedge ray artefacts in single-axis electron tomographic reconstructions
  • A simple Fourier filter for suppression of the missing wedge ray artefacts in single-axis electron tomographic reconstructions (en)
skos:prefLabel
  • A simple Fourier filter for suppression of the missing wedge ray artefacts in single-axis electron tomographic reconstructions
  • A simple Fourier filter for suppression of the missing wedge ray artefacts in single-axis electron tomographic reconstructions (en)
skos:notation
  • RIV/00216208:11110/14:10285231!RIV15-MSM-11110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GBP302/12/G157), P(GP13-32339P), S
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 1172
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11110/14:10285231
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Single-axis tilting; Missing wedge artefacts; Missing wedge; Electron tomography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [CF50F87F3502]
http://linked.open...i/riv/nazevZdroje
  • Journal of Structural Biology
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 186
http://linked.open...iv/tvurceVysledku
  • Kováčik, Lubomír
  • Matula, Pavel
  • Raška, Ivan
  • Jůda, Pavel
  • Hoeoeg, Johanna L.
  • Kereïche, Sami
http://linked.open...ain/vavai/riv/wos
  • 000334570200015
issn
  • 1047-8477
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.jsb.2014.02.004
http://localhost/t...ganizacniJednotka
  • 11110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software