About: Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The aim of the study was to verify differences between reference intervals for thyroid-stimulating hormone (TSH) and free thyroxine (FT4), as well as the cut-off for anti-thyroid peroxidase antibodies (TPO Ab) in pregnant women. Additionally, to compare these reference intervals with those recommended by the manufacturers for a healthy population. Levels of TSH, FT4, and TPO Ab were determined in a group of pregnant women (n = 216) with no history of thyroid dysfunction. Simultaneously, reference intervals for thyroid function tests were established with 7 different analytical systems representing those immunoassays most often used globally. The reference intervals for FT4 were slightly different, according to the system used by each manufacturer. Those for Architect, Centaur, Modular E170, and RIA Immunotech were slightly higher than those for Immulite 2500 and AIA 2000; the lowest being for UniCel DxI (8.13-13.2 pmol/L). For TSH, a higher interval (0.25-3.86 mU/L) is recommended for Modular E170 and IRMA Immunotech; and a lower one (0.17-2.81 mU/L) for Immulite 2500 and AIA 2000. The established cut-off limits for TPO-Ab differ according to the system used and are similar to those recommended by their manufacturers.
  • The aim of the study was to verify differences between reference intervals for thyroid-stimulating hormone (TSH) and free thyroxine (FT4), as well as the cut-off for anti-thyroid peroxidase antibodies (TPO Ab) in pregnant women. Additionally, to compare these reference intervals with those recommended by the manufacturers for a healthy population. Levels of TSH, FT4, and TPO Ab were determined in a group of pregnant women (n = 216) with no history of thyroid dysfunction. Simultaneously, reference intervals for thyroid function tests were established with 7 different analytical systems representing those immunoassays most often used globally. The reference intervals for FT4 were slightly different, according to the system used by each manufacturer. Those for Architect, Centaur, Modular E170, and RIA Immunotech were slightly higher than those for Immulite 2500 and AIA 2000; the lowest being for UniCel DxI (8.13-13.2 pmol/L). For TSH, a higher interval (0.25-3.86 mU/L) is recommended for Modular E170 and IRMA Immunotech; and a lower one (0.17-2.81 mU/L) for Immulite 2500 and AIA 2000. The established cut-off limits for TPO-Ab differ according to the system used and are similar to those recommended by their manufacturers. (en)
Title
  • Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems
  • Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems (en)
skos:prefLabel
  • Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems
  • Reference intervals for thyroid markers in early pregnancy determined by 7 different analytical systems (en)
skos:notation
  • RIV/00216208:11110/14:10284098!RIV15-MSM-11110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 41744
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11110/14:10284098
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • thyroid-stimulating hormone; reference interval; pregnancy; immunoassay; Thyroxine (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NO - Norské království
http://linked.open...ontrolniKodProRIV
  • [72B5C7951E8A]
http://linked.open...i/riv/nazevZdroje
  • Scandinavian Journal of Clinical and Laboratory Investigation
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 74
http://linked.open...iv/tvurceVysledku
  • Zima, Tomáš
  • Springer, Drahomíra
  • Bartos, Vladimir
http://linked.open...ain/vavai/riv/wos
  • 000334737700003
issn
  • 0036-5513
number of pages
http://bibframe.org/vocab/doi
  • 10.3109/00365513.2013.860617
http://localhost/t...ganizacniJednotka
  • 11110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 9 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software