About: MCNPX simulation of influence of cosmic rays on low-activity spectrometric measurements     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Germanium gamma spectrometers are effective instruments for low-activity measurement of a mixture of radionuclides in environmental samples, food samples, in materials released from nuclear facilities to the environment, etc. In such measurements cosmic rays have a significant contribution to the background signal. A Monte Carlo code MCNPXTM was used to calculate coaxial high-purity germanium (HPGe) detector pulse-height spectra caused by cosmic rays penetrating through shielding made of concrete and lead. Simulations were compared to two different measurements, one performed inside a 10 cm thick lead shielding and another done inside a larger chamber made of low-activity concrete and with several ceiling thicknesses. In the first experiment, a discrepancy was found between simulated and measured spectra by up to the factor of 4 at 2.62 MeV and slowly decreasing to unity at 13 MeV. It is assumed that the discrepancy between the measured and simulated spectra is caused by the simplification of muon energy losses treatment resulting in the underestimation of count rate in simulated pulse-height spectrum. Good agreement was obtained between simulation and measurement of differences of detector count rates in 662 keV and 1332 keV energy windows inside a concrete chamber with varying ceiling thickness. It is assumed that due to lower effective Z of concrete, delta electron bremsstrahlung has lower yield and the muon radiation energy losses start to be important at higher energies than in lead. As a result, the total contribution of these effects to the outputs of MCNPXTM simulations of concrete chamber is not dominant in the investigated energy windows and the simulation results are in a close agreement with the measurement.
  • Germanium gamma spectrometers are effective instruments for low-activity measurement of a mixture of radionuclides in environmental samples, food samples, in materials released from nuclear facilities to the environment, etc. In such measurements cosmic rays have a significant contribution to the background signal. A Monte Carlo code MCNPXTM was used to calculate coaxial high-purity germanium (HPGe) detector pulse-height spectra caused by cosmic rays penetrating through shielding made of concrete and lead. Simulations were compared to two different measurements, one performed inside a 10 cm thick lead shielding and another done inside a larger chamber made of low-activity concrete and with several ceiling thicknesses. In the first experiment, a discrepancy was found between simulated and measured spectra by up to the factor of 4 at 2.62 MeV and slowly decreasing to unity at 13 MeV. It is assumed that the discrepancy between the measured and simulated spectra is caused by the simplification of muon energy losses treatment resulting in the underestimation of count rate in simulated pulse-height spectrum. Good agreement was obtained between simulation and measurement of differences of detector count rates in 662 keV and 1332 keV energy windows inside a concrete chamber with varying ceiling thickness. It is assumed that due to lower effective Z of concrete, delta electron bremsstrahlung has lower yield and the muon radiation energy losses start to be important at higher energies than in lead. As a result, the total contribution of these effects to the outputs of MCNPXTM simulations of concrete chamber is not dominant in the investigated energy windows and the simulation results are in a close agreement with the measurement. (en)
Title
  • MCNPX simulation of influence of cosmic rays on low-activity spectrometric measurements
  • MCNPX simulation of influence of cosmic rays on low-activity spectrometric measurements (en)
skos:prefLabel
  • MCNPX simulation of influence of cosmic rays on low-activity spectrometric measurements
  • MCNPX simulation of influence of cosmic rays on low-activity spectrometric measurements (en)
skos:notation
  • RIV/00177016:_____/14:#0000866!RIV15-MSM-00177016
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • R, V
http://linked.open...iv/cisloPeriodika
  • February 2014
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 27726
http://linked.open...ai/riv/idVysledku
  • RIV/00177016:_____/14:#0000866
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Cosmic rays; Pulse-height spectrum; Low-activity measurement; Gamma-ray spectrometry; Monte Carlo simulation; MCNPX (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [EFC29E0CCDB9]
http://linked.open...i/riv/nazevZdroje
  • Radiation Physics and Chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 95
http://linked.open...iv/tvurceVysledku
  • Kovář, Petr
  • Šolc, Jaroslav
  • Dryák, Pavel
issn
  • 0969-806X
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.radphyschem.2012.12.034
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software