About: Bilateral Comparison of the ITS-90 realisation from 83,8058 K to 1357,77 K between CMI and SMU     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Project of bilateral comparison between CMI and SMU was initiated during December 2011. It was defined as the comparison of fixed point realizations of ITS-90 temperature scale. There were used fixed points from the triple point of Argon (83.8058 K) to the freezing point of Copper (1357.77 K). Comparisons were realized according to technical comparisons protocols T-K3, T-K4, etc. Except of standard procedures described in technical protocols, fixed points of Argon and Gallium were measured by direct comparison of these points. For the purpose of temperature measurements were used Standard Platinum Resistance Thermometers (SPRT) with long-stem and for higher temperatures was necessary to use high temperature SPRT’s. These measurements were also performed with pure-elements thermocouples (Pt/Au and Pt/Pd). CMI prepared an extra ultra-stable thermometer for each fixed point. After long term stabilization of each instrument, all the measurements in CMI and SMU were performed. In the next step, both laboratories analyzed acquired data for results and uncertainties evaluation. The results of both laboratories agree within their expanded uncertainties and they are summarized. Protocols made from these measurements are consistent with current procedures for the comparison of fixed points related to the ITS-90 temperature scale realization.
  • Project of bilateral comparison between CMI and SMU was initiated during December 2011. It was defined as the comparison of fixed point realizations of ITS-90 temperature scale. There were used fixed points from the triple point of Argon (83.8058 K) to the freezing point of Copper (1357.77 K). Comparisons were realized according to technical comparisons protocols T-K3, T-K4, etc. Except of standard procedures described in technical protocols, fixed points of Argon and Gallium were measured by direct comparison of these points. For the purpose of temperature measurements were used Standard Platinum Resistance Thermometers (SPRT) with long-stem and for higher temperatures was necessary to use high temperature SPRT’s. These measurements were also performed with pure-elements thermocouples (Pt/Au and Pt/Pd). CMI prepared an extra ultra-stable thermometer for each fixed point. After long term stabilization of each instrument, all the measurements in CMI and SMU were performed. In the next step, both laboratories analyzed acquired data for results and uncertainties evaluation. The results of both laboratories agree within their expanded uncertainties and they are summarized. Protocols made from these measurements are consistent with current procedures for the comparison of fixed points related to the ITS-90 temperature scale realization. (en)
Title
  • Bilateral Comparison of the ITS-90 realisation from 83,8058 K to 1357,77 K between CMI and SMU
  • Bilateral Comparison of the ITS-90 realisation from 83,8058 K to 1357,77 K between CMI and SMU (en)
skos:prefLabel
  • Bilateral Comparison of the ITS-90 realisation from 83,8058 K to 1357,77 K between CMI and SMU
  • Bilateral Comparison of the ITS-90 realisation from 83,8058 K to 1357,77 K between CMI and SMU (en)
skos:notation
  • RIV/00177016:_____/13:#0000990!RIV15-MSM-00177016
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 63340
http://linked.open...ai/riv/idVysledku
  • RIV/00177016:_____/13:#0000990
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • fixed point; comparison; ITS-90 (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [DE3D42B10B0D]
http://linked.open...v/mistoKonaniAkce
  • Funchal, Madeira
http://linked.open...i/riv/nazevZdroje
  • Symposium on Temperature and Thermal Measurements in Industry and Science
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Strnad, Radek
  • Šindelář, Martin
  • Koval, M.
  • Pavlásek, P.
  • Ďuriš, S.
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
https://schema.org/isbn
  • 978-972-8574-15-4
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.