Attributes | Values |
---|
rdf:type
| |
Description
| - A frequency comparison was carried out between iodine-stabilized Nd:YAG lasers at 532 nm from the Bureau International des Poids et Mesures, the Centre for Metrology and Accreditation, the Czech Metrology Institute, and the Bureau National de Metrologie-Institut National de Metrologie. The frequency differences between lasers, as well as the frequency reproducibility of each system, were investigated. Pressure-, modulation-, and power-induced shifts were studied. A frequency dispersion (1 s) of 3.5 kHz (6.2 x 10-12 in relative terms) with an average reproducibility for each laser of the order of 0.4 kHz (7.1 x 10-13 in relative terms) was observed over the duration of the comparison. Relative stabilities better than 1x 10-13 at 1 s were demonstrated for the third-harmonic systems.
- A frequency comparison was carried out between iodine-stabilized Nd:YAG lasers at 532 nm from the Bureau International des Poids et Mesures, the Centre for Metrology and Accreditation, the Czech Metrology Institute, and the Bureau National de Metrologie-Institut National de Metrologie. The frequency differences between lasers, as well as the frequency reproducibility of each system, were investigated. Pressure-, modulation-, and power-induced shifts were studied. A frequency dispersion (1 s) of 3.5 kHz (6.2 x 10-12 in relative terms) with an average reproducibility for each laser of the order of 0.4 kHz (7.1 x 10-13 in relative terms) was observed over the duration of the comparison. Relative stabilities better than 1x 10-13 at 1 s were demonstrated for the third-harmonic systems. (en)
|
Title
| - A comparison of 127I2-stabilized frequency-doubled Nd:YAG lasers at the BIPM, comparison in May 2001
- A comparison of 127I2-stabilized frequency-doubled Nd:YAG lasers at the BIPM, comparison in May 2001 (en)
|
skos:prefLabel
| - A comparison of 127I2-stabilized frequency-doubled Nd:YAG lasers at the BIPM, comparison in May 2001
- A comparison of 127I2-stabilized frequency-doubled Nd:YAG lasers at the BIPM, comparison in May 2001 (en)
|
skos:notation
| - RIV/00177016:_____/03:#0000126!RIV11-MPO-00177016
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00177016:_____/03:#0000126
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - metrology; frequency stabilized; YAG (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - US - Spojené státy americké
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| |
issn
| |
number of pages
| |