About: Recurrent stroke and patent foramen ovale: a systematic review and meta-analysis     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Background and Purpose-Recurrent cerebrovascular events are frequent in medically treated patients with patent foramen ovale (PFO), but it still remains unclear whether PFO is a causal or an incidental finding. Further uncertainty exists on whether the size of functional shunting could represent a potential risk factor. The aim of the present study was to evaluate if the presence of PFO is associated with an increased risk of recurrent stroke or transient ischemic attack and to investigate further if this relationship is related to the shunt size. Methods-We conducted a systematic review and meta-analysis according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines of all available prospective studies reporting recurrent cerebrovascular events defined as cryptogenic stroke and transient ischemic attacks in medically treated patients with PFO diagnosed by echocardiography or transcranial sonography. Results-We identified 14 eligible studies including a total of 4251 patients. Patients with stroke with PFO did not have a higher risk of the combined outcome of recurrent stroke/transient ischemic attack (risk ratio=1.18; 95% confidence interval=0.78-1.79; P=0.43) or in the incidence of recurrent strokes (risk ratio =0.85; 95% confidence interval=0.59-1.22; P=0.37) in comparison with stroke patients without PFO. In addition, PFO size was not associated with the risk of recurrent stroke or transient ischemic attack. We also documented no evidence of heterogeneity across the included studies. Conclusions-Our findings indicate that medically treated patients with PFO do not have a higher risk for recurrent cryptogenic cerebrovascular events, compared with those without PFO. No relation between the degree of PFO and the risk of future cerebrovascular events was identified.
  • Background and Purpose-Recurrent cerebrovascular events are frequent in medically treated patients with patent foramen ovale (PFO), but it still remains unclear whether PFO is a causal or an incidental finding. Further uncertainty exists on whether the size of functional shunting could represent a potential risk factor. The aim of the present study was to evaluate if the presence of PFO is associated with an increased risk of recurrent stroke or transient ischemic attack and to investigate further if this relationship is related to the shunt size. Methods-We conducted a systematic review and meta-analysis according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines of all available prospective studies reporting recurrent cerebrovascular events defined as cryptogenic stroke and transient ischemic attacks in medically treated patients with PFO diagnosed by echocardiography or transcranial sonography. Results-We identified 14 eligible studies including a total of 4251 patients. Patients with stroke with PFO did not have a higher risk of the combined outcome of recurrent stroke/transient ischemic attack (risk ratio=1.18; 95% confidence interval=0.78-1.79; P=0.43) or in the incidence of recurrent strokes (risk ratio =0.85; 95% confidence interval=0.59-1.22; P=0.37) in comparison with stroke patients without PFO. In addition, PFO size was not associated with the risk of recurrent stroke or transient ischemic attack. We also documented no evidence of heterogeneity across the included studies. Conclusions-Our findings indicate that medically treated patients with PFO do not have a higher risk for recurrent cryptogenic cerebrovascular events, compared with those without PFO. No relation between the degree of PFO and the risk of future cerebrovascular events was identified. (en)
Title
  • Recurrent stroke and patent foramen ovale: a systematic review and meta-analysis
  • Recurrent stroke and patent foramen ovale: a systematic review and meta-analysis (en)
skos:prefLabel
  • Recurrent stroke and patent foramen ovale: a systematic review and meta-analysis
  • Recurrent stroke and patent foramen ovale: a systematic review and meta-analysis (en)
skos:notation
  • RIV/00159816:_____/14:00061208!RIV15-MSM-00159816
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.100/02/0123)
http://linked.open...iv/cisloPeriodika
  • 11
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
  • Tsivgoulis, Georgios
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 41661
http://linked.open...ai/riv/idVysledku
  • RIV/00159816:_____/14:00061208
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • foramen ovale, patent , ischemic attack, transient , stroke, transcranial Doppler ultrasonography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [04D73BBF5185]
http://linked.open...i/riv/nazevZdroje
  • Stroke
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 45
http://linked.open...iv/tvurceVysledku
  • Tsivgoulis, Georgios
  • Parissis, J.
  • Katsanos, A. H.
  • Bogiatzi, C.
  • Frogoudaki, A.
  • Giannopoulos, S.
  • Safouris, A.
  • Spence, D.
  • Voumvourakis, K.
http://linked.open...ain/vavai/riv/wos
  • 000344351500046
issn
  • 0039-2499
number of pages
http://bibframe.org/vocab/doi
  • 10.1161/STROKEAHA.114.007109
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software