About: Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Rapid healing of vascular stents is important for avoiding complications associated with stent thrombosis, restenosis, and bleeding related to antiplatelet drugs. Magnetic forces can be used to capture iron-labeled endothelial cells immediately following stent implantation, thereby promoting healing. This strategy requires the development of a magnetic stent that is biocompatible and functional. We designed a stent from the weakly ferromagnetic 2205 stainless steel using finite element analysis. The final design exhibited a principal strain below the fracture limit of 30% during crimping and expansion. Ten stents were fabricated and validated experimentally for fracture resistance. Another 10 stents magnetized with a neodymium magnet showed a magnetic field in the range of 100-750 mG. The retained magnetism was sufficiently strong to capture magnetically-labeled endothelial cells on the stent surfaces during in vitro studies. Magnetically-labeled endothelial cell capture was also verified in vivo after 7 days following coronary implantation in 4 pigs using histological analysis. Images of the stented blood vessels showed uniform endothelium formation on the stent surfaces. In conclusion, we have designed a ferromagnetic bare metal stent from 2205 stainless steel that is functional, biocompatible, and able to capture and retain magnetically-labeled endothelial cells in order to promote rapid stent healing.
  • Rapid healing of vascular stents is important for avoiding complications associated with stent thrombosis, restenosis, and bleeding related to antiplatelet drugs. Magnetic forces can be used to capture iron-labeled endothelial cells immediately following stent implantation, thereby promoting healing. This strategy requires the development of a magnetic stent that is biocompatible and functional. We designed a stent from the weakly ferromagnetic 2205 stainless steel using finite element analysis. The final design exhibited a principal strain below the fracture limit of 30% during crimping and expansion. Ten stents were fabricated and validated experimentally for fracture resistance. Another 10 stents magnetized with a neodymium magnet showed a magnetic field in the range of 100-750 mG. The retained magnetism was sufficiently strong to capture magnetically-labeled endothelial cells on the stent surfaces during in vitro studies. Magnetically-labeled endothelial cell capture was also verified in vivo after 7 days following coronary implantation in 4 pigs using histological analysis. Images of the stented blood vessels showed uniform endothelium formation on the stent surfaces. In conclusion, we have designed a ferromagnetic bare metal stent from 2205 stainless steel that is functional, biocompatible, and able to capture and retain magnetically-labeled endothelial cells in order to promote rapid stent healing. (en)
Title
  • Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells
  • Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells (en)
skos:prefLabel
  • Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells
  • Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells (en)
skos:notation
  • RIV/00159816:_____/14:00061154!RIV15-MSM-00159816
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.100/02/0123)
http://linked.open...iv/cisloPeriodika
  • 12
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 10426
http://linked.open...ai/riv/idVysledku
  • RIV/00159816:_____/14:00061154
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Thrombosis; Restenosis; Finite element analysis; Endothelialization; Stent healing; Magnetic stent (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [459664556026]
http://linked.open...i/riv/nazevZdroje
  • Annals of Biomedical Engineering
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 42
http://linked.open...iv/tvurceVysledku
  • Hlinomaz, Ota
  • Klabusay, Martin
  • Dragomir-Daescu, D.
  • Sandhu, G. S.
  • Tefft, B.J
  • Uthamaraj, S.
http://linked.open...ain/vavai/riv/wos
  • 000345394000004
issn
  • 0090-6964
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s10439-014-1088-3
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software