About: Magnetizable Duplex Steel Stents Enable Endothelial Cell Capture     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Emerging medical nanotechnology applications often utilize magnetic forces to guide the movement of superparamagnetic particle linked cells and drugs in order to achieve a therapeutic effect. Superparamagnetic particle labeled endothelial cells have previously been captured on the surface of prototype nickel-plated stents in proof of concept studies. Facilitated endothelialization may help improve the healing of stented arteries and reduce the risk of stent thrombosis and restenosis. Extensive evaluation of candidate materials led to the development of a magnetizable 2205 duplex stainless steel stent. Magnetic field strengths of approximately 630 mG were induced within these stents by holding them in close proximity to a 0.7 T rare earth magnet. The magnetic field strength was reliably maintained over several days, but was partially reduced upon mild mechanical shock or plastic deformation. Mechanical testing demonstrated that stents could withstand crimping and expansion necessary for vascular implantation; however, magnetic field strength was significantly reduced. When placed in an endothelial cell suspension of 1 x 10(6) cells/mL, magnetized stents captured approximately 310 cells/mm(2) compared to approximately 35 cells/mm(2) for non-magnetized control stents. These data provide quantitative support to the observation that low level magnetization of stentsmay be adequate to attract labeled, autologous, blood-derived endothelial outgrowth cells following stent placement. This, in turn, may lead to more rapid and complete healing of stented arteries with a concomitant improvement in stent performance.
  • Emerging medical nanotechnology applications often utilize magnetic forces to guide the movement of superparamagnetic particle linked cells and drugs in order to achieve a therapeutic effect. Superparamagnetic particle labeled endothelial cells have previously been captured on the surface of prototype nickel-plated stents in proof of concept studies. Facilitated endothelialization may help improve the healing of stented arteries and reduce the risk of stent thrombosis and restenosis. Extensive evaluation of candidate materials led to the development of a magnetizable 2205 duplex stainless steel stent. Magnetic field strengths of approximately 630 mG were induced within these stents by holding them in close proximity to a 0.7 T rare earth magnet. The magnetic field strength was reliably maintained over several days, but was partially reduced upon mild mechanical shock or plastic deformation. Mechanical testing demonstrated that stents could withstand crimping and expansion necessary for vascular implantation; however, magnetic field strength was significantly reduced. When placed in an endothelial cell suspension of 1 x 10(6) cells/mL, magnetized stents captured approximately 310 cells/mm(2) compared to approximately 35 cells/mm(2) for non-magnetized control stents. These data provide quantitative support to the observation that low level magnetization of stentsmay be adequate to attract labeled, autologous, blood-derived endothelial outgrowth cells following stent placement. This, in turn, may lead to more rapid and complete healing of stented arteries with a concomitant improvement in stent performance. (en)
Title
  • Magnetizable Duplex Steel Stents Enable Endothelial Cell Capture
  • Magnetizable Duplex Steel Stents Enable Endothelial Cell Capture (en)
skos:prefLabel
  • Magnetizable Duplex Steel Stents Enable Endothelial Cell Capture
  • Magnetizable Duplex Steel Stents Enable Endothelial Cell Capture (en)
skos:notation
  • RIV/00159816:_____/13:00060589!RIV14-MSM-00159816
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.100/02/0123)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 85746
http://linked.open...ai/riv/idVysledku
  • RIV/00159816:_____/13:00060589
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • stents; magnetic; Endothelial cells (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [A7BAA536B427]
http://linked.open...i/riv/nazevZdroje
  • IEEE Transactions on Magnetics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 49
http://linked.open...iv/tvurceVysledku
  • Klabusay, Martin
  • Dragomir-Daescu, Dan
  • Gooden, Janelle Y.
  • Harburn, J. Jonathan
  • Holmes, David R., Jr.
  • Sandhu, Gurpreet S.
  • Simari, Robert D.
  • Tefft, Brandon J.
  • Uthamaraj, Susheil
http://linked.open...ain/vavai/riv/wos
  • 000312831500052
issn
  • 0018-9464
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/TMAG.2012.2224326
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software