About: Predicting axillary sentinel node status in patients with primary breast cancer     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The study is based on retrospective analysis of medical records of 170 patients diagnosed with primary breast cancer. These women underwent primary surgery of the breast and axilla in which at least one sentinel lymph node was obtained. Logistic regression has been employed to construct a model predicting axillary sentinel lymph node involvement using preoperative and postoperative tumor characteristics. Postoperative model uses tumor features obtained from definitive histology samples. Its predictive capability expressed by receiver operating characteristic curve is good, area under curve (AUC) equals to 0.78. The comparison between preoperative and postoperative results showed the only significant differences in values of histopathological grading; we have considered grading not reliably stated before surgery. In preoperative model only the characteristics available and reliably stated at the time of diagnoses were used. The predictive capability of this model is only fair when using the data available at the time of diagnosis (AUC = 0.66). We conclude, that predictive models based on postoperative values enable to reliably estimate the likelihood of occurrence of axillary sentinel node(s) metastases. This can be used in clinical practice in case surgical procedure is divided into two steps, breast surgery first and axillary surgery thereafter. Even if preoperative values were not significantly different from postoperative ones (except for grading), the preoperative model predictive capability is lower compared to postoperative values. The reason for this worse prediction was identified in imperfect preoperative diagnostic.
  • The study is based on retrospective analysis of medical records of 170 patients diagnosed with primary breast cancer. These women underwent primary surgery of the breast and axilla in which at least one sentinel lymph node was obtained. Logistic regression has been employed to construct a model predicting axillary sentinel lymph node involvement using preoperative and postoperative tumor characteristics. Postoperative model uses tumor features obtained from definitive histology samples. Its predictive capability expressed by receiver operating characteristic curve is good, area under curve (AUC) equals to 0.78. The comparison between preoperative and postoperative results showed the only significant differences in values of histopathological grading; we have considered grading not reliably stated before surgery. In preoperative model only the characteristics available and reliably stated at the time of diagnoses were used. The predictive capability of this model is only fair when using the data available at the time of diagnosis (AUC = 0.66). We conclude, that predictive models based on postoperative values enable to reliably estimate the likelihood of occurrence of axillary sentinel node(s) metastases. This can be used in clinical practice in case surgical procedure is divided into two steps, breast surgery first and axillary surgery thereafter. Even if preoperative values were not significantly different from postoperative ones (except for grading), the preoperative model predictive capability is lower compared to postoperative values. The reason for this worse prediction was identified in imperfect preoperative diagnostic. (en)
Title
  • Predicting axillary sentinel node status in patients with primary breast cancer
  • Predicting axillary sentinel node status in patients with primary breast cancer (en)
skos:prefLabel
  • Predicting axillary sentinel node status in patients with primary breast cancer
  • Predicting axillary sentinel node status in patients with primary breast cancer (en)
skos:notation
  • RIV/00064211:_____/13:#0000269!RIV14-MZ0-00064211
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, V
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 98554
http://linked.open...ai/riv/idVysledku
  • RIV/00064211:_____/13:#0000269
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • reast cancer; tumor characteristics; sentinel node metastasis; preoperative diagnosis; predictive model (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • SK - Slovenská republika
http://linked.open...ontrolniKodProRIV
  • [1543ECE771D3]
http://linked.open...i/riv/nazevZdroje
  • Neoplasma
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 60
http://linked.open...iv/tvurceVysledku
  • Halaška, Michael
  • Petruželka, Luboš
  • Kolářová, H.
  • Trnková, M.
  • Šottner, Oldřich
  • Pecha, V.
  • Otčenášek, M.
  • Skovajsová, M.
  • Záhumenský, J.
  • Kolařík, D.
http://linked.open...ain/vavai/riv/wos
  • 000323235300015
issn
  • 0028-2685
number of pages
http://bibframe.org/vocab/doi
  • 10.4149/neo_2013_045
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software