About: Effect of MGuard Net Protective Stent on the Release of Troponin I in Patients With Acute Coronary Syndromes A Randomized Controlled Trial     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • This study was designed to determine whether the treatment of patients with unstable angina pectoris or non-Q-wave myocardial infarction with a stent containing a protection net to prevent coronary microembolization affects the severity of biomarker release. The MGuard stent (InspireMD, Tel Aviv, Israel) was designed as a plaque/thrombus-trapping device, using a conventional bare metal stent covered with an ultrathin, flexible mesh net. We hypothesized that this stent would partly eliminate distal embolization and decrease subsequent troponin I (TnI) release. Forty-six acute coronary syndrome patients referred for percutaneous coronary intervention (PCI) were included and randomized in this study. Serum concentrations of TnI were measured prior to, as well as 24 and 48 hours after, the PCI procedure. Technical success was 95% and 100% in the MGuard group and non-MGuard group, respectively. A transient no-reflow phenomenon was observed in one interventional procedure in each group of patients (5% versus 4%; NS). Two patients (one in each group) died during the hospital stay. There was no statistically significant difference in median post-procedural TnI levels in either group. The results suggest that coronary stenting with a stent system containing a protection net to prevent coronary microembolization (eg the MGuard stent) in patients with acute coronary syndromes does not decrease procedural myocardial injury, as measured by TnI release. It seems likely that stenting with the MGuard stent is feasible, however, its safety should be verified in larger studies. (Int Heart J 2011; 52: 203-206)
  • This study was designed to determine whether the treatment of patients with unstable angina pectoris or non-Q-wave myocardial infarction with a stent containing a protection net to prevent coronary microembolization affects the severity of biomarker release. The MGuard stent (InspireMD, Tel Aviv, Israel) was designed as a plaque/thrombus-trapping device, using a conventional bare metal stent covered with an ultrathin, flexible mesh net. We hypothesized that this stent would partly eliminate distal embolization and decrease subsequent troponin I (TnI) release. Forty-six acute coronary syndrome patients referred for percutaneous coronary intervention (PCI) were included and randomized in this study. Serum concentrations of TnI were measured prior to, as well as 24 and 48 hours after, the PCI procedure. Technical success was 95% and 100% in the MGuard group and non-MGuard group, respectively. A transient no-reflow phenomenon was observed in one interventional procedure in each group of patients (5% versus 4%; NS). Two patients (one in each group) died during the hospital stay. There was no statistically significant difference in median post-procedural TnI levels in either group. The results suggest that coronary stenting with a stent system containing a protection net to prevent coronary microembolization (eg the MGuard stent) in patients with acute coronary syndromes does not decrease procedural myocardial injury, as measured by TnI release. It seems likely that stenting with the MGuard stent is feasible, however, its safety should be verified in larger studies. (Int Heart J 2011; 52: 203-206) (en)
Title
  • Effect of MGuard Net Protective Stent on the Release of Troponin I in Patients With Acute Coronary Syndromes A Randomized Controlled Trial
  • Effect of MGuard Net Protective Stent on the Release of Troponin I in Patients With Acute Coronary Syndromes A Randomized Controlled Trial (en)
skos:prefLabel
  • Effect of MGuard Net Protective Stent on the Release of Troponin I in Patients With Acute Coronary Syndromes A Randomized Controlled Trial
  • Effect of MGuard Net Protective Stent on the Release of Troponin I in Patients With Acute Coronary Syndromes A Randomized Controlled Trial (en)
skos:notation
  • RIV/00064203:_____/11:7166!RIV12-MZ0-00064203
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(NT11401)
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 196353
http://linked.open...ai/riv/idVysledku
  • RIV/00064203:_____/11:7166
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Stent; Acute coronary syndrome; Coronary stenosis; distal embolization; microembolization; intervention; experience (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • JP - Japonsko
http://linked.open...ontrolniKodProRIV
  • [4E4F471187F7]
http://linked.open...i/riv/nazevZdroje
  • International Heart Journal
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 52
http://linked.open...iv/tvurceVysledku
  • Hájek, Petr
  • Malý, Martin
  • Martinkovičová, Lucia
  • Tomašov, Pavol
  • Veselka, Josef
  • Zemánek, David
http://linked.open...ain/vavai/riv/wos
  • 000296130400002
issn
  • 1349-2365
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 75 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software