| - Myocardial perforation caused by pacing lead is a rare complication of pacemaker implantation. It is associated with the use of both activeand passive-fixation leads, but active fixation can increase the risk of perforation. We report the patient in whom an active ventricular lead caused perforation of right ventricular wall. The patient was readmitted to hospital on 5th day after pacemaker implantation for complete failure of pacing with symptoms like dizziness and faintness. Afterwards, using echocardiogram and X-rays, diagnosis of perforation was revealed. There were signs of small-sized pericardial effusion around the distal end of lead. Perforating electrode was withdrawn without complications and immediately replaced by new passive-fixation lead. Key words: pacing lead, perforation, pericardial effusion (en)
- Perforace myokardu stimulační elektrodou je vzácná komplikace implantace kardiostimulátoru. Použití elektrody s aktivní fixací může mírně zvýšit riziko penetrace. Kazuistika referuje o nemocném s perforací pravé komory stimulační elektrodou. Příznakem byla slabost a prekolapsy při neúčinné stimulaci. Diagnoza byla potvrzena pomocí echokardiografie a skiaskopie hrudníku. Okolo hrotu pravé komory byl malý perikardiální výpotek. Elektroda byla odstraněna bez komplikací volnou trakcí, v jedné době byla implantována nová elektroda s pasivní fixací.
- Perforace myokardu stimulační elektrodou je vzácná komplikace implantace kardiostimulátoru. Použití elektrody s aktivní fixací může mírně zvýšit riziko penetrace. Kazuistika referuje o nemocném s perforací pravé komory stimulační elektrodou. Příznakem byla slabost a prekolapsy při neúčinné stimulaci. Diagnoza byla potvrzena pomocí echokardiografie a skiaskopie hrudníku. Okolo hrotu pravé komory byl malý perikardiální výpotek. Elektroda byla odstraněna bez komplikací volnou trakcí, v jedné době byla implantována nová elektroda s pasivní fixací. (cs)
|
Title
| - Komplikace trvalé kardiostimulace: perforace myokardu komorovou stimulační elektrodou
- Myocardial perforation caused by pacing lead (en)
- Komplikace trvalé kardiostimulace: perforace myokardu komorovou stimulační elektrodou (cs)
|
skos:prefLabel
| - Komplikace trvalé kardiostimulace: perforace myokardu komorovou stimulační elektrodou
- Myocardial perforation caused by pacing lead (en)
- Komplikace trvalé kardiostimulace: perforace myokardu komorovou stimulační elektrodou (cs)
|
skos:notation
| - RIV/00023884:_____/07:#0001903!RIV12-MZ0-00023884
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00023884:_____/07:#0001903
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - pacing lead, perforation, pericardial effusion (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Intervenční a akutní kardiologie
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Petrů, Jan
- Táborský, Miloš
|
issn
| |
number of pages
| |