About: The comparison of methods for evaluation of FDG-PET in the diagnosis of temporal lobe epilepsy     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The aim of this work was to define the cut-off point for different methods of FDG-PET evaluation of temporal lobe epilepsy (TLE) and to define accuracy of these methods. 58 consecutive patients with proven hippocampal sclerosis (HS), and 27 oncologic patients without brain involvement (control group) were investigated by PET. ROC analysis was utilized for the assessment of accuracy of semi-quantitative parameters of manual evaluation by two operators as well as automated brain analysis by two software. Results support hypothesis, that FDG-PET is a reliable diagnostic tool for discrimination between patients with HS and control group. Sensitivity and specificity is at the level of 90% approximately, regardless the method of evaluation we used. Furthermore FDG-PET is capable to correctly predict the side of operation in 100% of patients with HS. Completely automated analysis is less laborious and operator’s independent. It gives the same results as careful manual assessment.
  • The aim of this work was to define the cut-off point for different methods of FDG-PET evaluation of temporal lobe epilepsy (TLE) and to define accuracy of these methods. 58 consecutive patients with proven hippocampal sclerosis (HS), and 27 oncologic patients without brain involvement (control group) were investigated by PET. ROC analysis was utilized for the assessment of accuracy of semi-quantitative parameters of manual evaluation by two operators as well as automated brain analysis by two software. Results support hypothesis, that FDG-PET is a reliable diagnostic tool for discrimination between patients with HS and control group. Sensitivity and specificity is at the level of 90% approximately, regardless the method of evaluation we used. Furthermore FDG-PET is capable to correctly predict the side of operation in 100% of patients with HS. Completely automated analysis is less laborious and operator’s independent. It gives the same results as careful manual assessment. (en)
  • Cílem této práce bylo definovat hraniční hodnotu pro různé metody vyhodnocení FDG-PET u temporální epilepsie (TLE) a definovat přesnost těchto metod. 58 konsekutivních pacientů s prokázanou hippokampální sklerózou (HS) a 27 onkologických pacientů bez postižení mozku (kontrolní skupina) bylo vyšetřeno pomocí PET. ROC analýza byla použita pro vyhodnocení přesnosti semikvantitativních parametrů manuálního vyhodnocení 2 operátory a také automatického vyhodnocení 2 programy. Výsledky podporují hypotézu, že FDG-PET je spolehlivý diagnostický nástroj pro odlišení pacientů s HS od kontrolní skupiny. Senzitivita a specificita je kolem 90 % bez ohledu použitou metodu. Navíc FDG-PET je schopna správně predikovat stranu operace ve 100 % pacientů s HS. Zcela automatizovaná analýza je méně pracná a nezávislá na operátorovi. Dává stejné výsledky jako pečlivé manuální vyhodnocení. (cs)
Title
  • The comparison of methods for evaluation of FDG-PET in the diagnosis of temporal lobe epilepsy
  • Porovnání metod pro vyhodnocení FDG-PET při diagnostice temporální epilepsie (cs)
  • The comparison of methods for evaluation of FDG-PET in the diagnosis of temporal lobe epilepsy (en)
skos:prefLabel
  • The comparison of methods for evaluation of FDG-PET in the diagnosis of temporal lobe epilepsy
  • Porovnání metod pro vyhodnocení FDG-PET při diagnostice temporální epilepsie (cs)
  • The comparison of methods for evaluation of FDG-PET in the diagnosis of temporal lobe epilepsy (en)
skos:notation
  • RIV/00023884:_____/07:#0000004!RIV08-MZ0-00023884
http://linked.open.../vavai/riv/strany
  • S320-S321
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(NR8843)
http://linked.open...iv/cisloPeriodika
  • Suppl. 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 414352
http://linked.open...ai/riv/idVysledku
  • RIV/00023884:_____/07:#0000004
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • FDG; PET; temporal lobe epilepsy (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [05880766B421]
http://linked.open...i/riv/nazevZdroje
  • European Journal of nuclear medicine and molecular imaging
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 34
http://linked.open...iv/tvurceVysledku
  • Bělohlávek, O.
  • Jarůšková, M.
issn
  • 1619-7070
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software