About: Manometric perfusion test in biliary strictures treatment     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Background/Aims: To assess the biliary manometric perfusion test (BMPT) for evaluating success in treating benign biliary strictures. Methodology: During 2003 to 2010, 29 patients were subjected to BMPT after percutaneous balloon dilatation treatment. Intrabiliary pressure less than 20cm of water was considered the success threshold. Results of BMPT evaluation were retrospectively compared with a similar group where the standard clinical test was used for evaluating treatment success. The clinical test group included 21 patients treated for biliary strictures from 1994 to 2006. Results: The two groups were statistically similar by age and gender. The BMPT group was tested without complications and pressure inside the biliary tree was less than 20cm of water in 27 of 29 patients. Subsequently, catheters were removed from all 27. Three patients required re-interventions 13 days, 11 months and 32 months later. Kaplan-Meier survival analysis showed that the probability of biliary patency at 3 year was 82.2%. There was no significant difference between groups by this measure (log rank test, p=0.624). Conclusions: The manometric test is an alternative for evaluating success in treating benign biliary strictures. It is simple, less time-consuming, economical, safe, effective and more comfortable for patients than the clinical test.
  • Background/Aims: To assess the biliary manometric perfusion test (BMPT) for evaluating success in treating benign biliary strictures. Methodology: During 2003 to 2010, 29 patients were subjected to BMPT after percutaneous balloon dilatation treatment. Intrabiliary pressure less than 20cm of water was considered the success threshold. Results of BMPT evaluation were retrospectively compared with a similar group where the standard clinical test was used for evaluating treatment success. The clinical test group included 21 patients treated for biliary strictures from 1994 to 2006. Results: The two groups were statistically similar by age and gender. The BMPT group was tested without complications and pressure inside the biliary tree was less than 20cm of water in 27 of 29 patients. Subsequently, catheters were removed from all 27. Three patients required re-interventions 13 days, 11 months and 32 months later. Kaplan-Meier survival analysis showed that the probability of biliary patency at 3 year was 82.2%. There was no significant difference between groups by this measure (log rank test, p=0.624). Conclusions: The manometric test is an alternative for evaluating success in treating benign biliary strictures. It is simple, less time-consuming, economical, safe, effective and more comfortable for patients than the clinical test. (en)
Title
  • Manometric perfusion test in biliary strictures treatment
  • Manometric perfusion test in biliary strictures treatment (en)
skos:prefLabel
  • Manometric perfusion test in biliary strictures treatment
  • Manometric perfusion test in biliary strictures treatment (en)
skos:notation
  • RIV/00023001:_____/12:00055864!RIV13-MZ0-00023001
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(NS10274), V
http://linked.open...iv/cisloPeriodika
  • 117
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 148052
http://linked.open...ai/riv/idVysledku
  • RIV/00023001:_____/12:00055864
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Manometric perfusion test; Percutaneous transhepatic drainage; Balloon dilatation; Biliary tract; Benign strictures (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GR - Řecká republika
http://linked.open...ontrolniKodProRIV
  • [310BE2F0EA19]
http://linked.open...i/riv/nazevZdroje
  • Hepato-gastroenterology
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 59
http://linked.open...iv/tvurceVysledku
  • Fraňková, Soňa
  • Peregrin, Jan
  • Koecher, Martin
  • Bilkova, Alena
  • Cerna, Marie
  • Havlik, Roman
  • Kozak, Jiří
  • Panek, Jiří
  • Thomas, Rohit Philip
  • Valek, Vlastimil
  • Zapletalova, Jana
http://linked.open...ain/vavai/riv/wos
  • 000307143100008
issn
  • 0172-6390
number of pages
http://bibframe.org/vocab/doi
  • 10.5754/hge11095
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software