About: Particle Image Velocimetry Measurement in the Model of Vascular Anastomosis     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Měření proudového pole v modelu cévní anastomozy metodou PIV. (cs)
  • Neointimal hyperplasia is the most common complication of all forms of arterial reconstructions. This response of the vascular wall to injury is influenced by many factors, especially, but not limited to, by the hemodynamic profile in the area of vascular anastomosis and in its close proximity. To eliminate this negative influence of hemodynamics on progression of neointimal hyperplasia, we tried to develop anastomosis with optimal hemodynamic parameters. In our experimental study we used Particle Image Velocimetry measurement and 3D blood flow simulation for studying flow characteristics for different length and angles of anastomoses. Based on our experimental studies and numerical simulations we believe that anastomosis with smaller angle demonstrates better hemodynamic parameters, optimal angle being less than 30 dg. Length of anastomosis in this smaller angle anastomosis is app. 2-2.5 of native vessel diameter.
  • Neointimal hyperplasia is the most common complication of all forms of arterial reconstructions. This response of the vascular wall to injury is influenced by many factors, especially, but not limited to, by the hemodynamic profile in the area of vascular anastomosis and in its close proximity. To eliminate this negative influence of hemodynamics on progression of neointimal hyperplasia, we tried to develop anastomosis with optimal hemodynamic parameters. In our experimental study we used Particle Image Velocimetry measurement and 3D blood flow simulation for studying flow characteristics for different length and angles of anastomoses. Based on our experimental studies and numerical simulations we believe that anastomosis with smaller angle demonstrates better hemodynamic parameters, optimal angle being less than 30 dg. Length of anastomosis in this smaller angle anastomosis is app. 2-2.5 of native vessel diameter. (en)
Title
  • Particle Image Velocimetry Measurement in the Model of Vascular Anastomosis
  • Particle Image Velocimetry Measurement in the Model of Vascular Anastomosis (en)
  • Měření proudového pole v modelu cévní anastomozy metodou PIV (cs)
skos:prefLabel
  • Particle Image Velocimetry Measurement in the Model of Vascular Anastomosis
  • Particle Image Velocimetry Measurement in the Model of Vascular Anastomosis (en)
  • Měření proudového pole v modelu cévní anastomozy metodou PIV (cs)
skos:notation
  • RIV/68407700:21220/07:02136960!RIV08-GA0-21220___
http://linked.open.../vavai/riv/strany
  • 75;86
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA101/05/0675)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 440712
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/07:02136960
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Computational fluid dynamics; Neointimal hyperplasia; Particle Image Velocimetry; Vascular anastomosis; Wall shear stress (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [18E801A73689]
http://linked.open...i/riv/nazevZdroje
  • Prague Medical Report
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 108
http://linked.open...iv/tvurceVysledku
  • Tůma, Jan
  • Matěcha, Jan
  • Netřebská, Hana
  • Vik, K.
  • Adamec, Josef
  • Lindner, J.
  • Tošovský, J.
  • Grus, T.
issn
  • 1214-6994
number of pages
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software