About: Time resolved emission measurement in double-pulse LIBS     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • For the orthogonal reheating mode, double pulse LIBS experimental setup with ICCD and PMT was designed. The double pulse LIBS plasma is created with a system of two Q switched Nd:YAG lasers. The two lasers (UP-266 MACRO, New Wave and Quantel Brilliant) are operated at the fourth harmonic frequency (266 nm) and at the fundamental wavelength of 1064 nm, respectively. The laser induced plasma radiation is transported by a fiber optic system onto the entrance slit of a monochromator (Jobin Yvon TRIAX 320). ICCD detector (Jobin Yvon Horiba) or a photomultiplier (Hamamatsu) gated by a laboratory built control unit are employed as detectors. For the gate time delay monitoring and time resolved signal recording, a digital storage oscilloscope Tektronix TDS 1012 is utilized.
  • For the orthogonal reheating mode, double pulse LIBS experimental setup with ICCD and PMT was designed. The double pulse LIBS plasma is created with a system of two Q switched Nd:YAG lasers. The two lasers (UP-266 MACRO, New Wave and Quantel Brilliant) are operated at the fourth harmonic frequency (266 nm) and at the fundamental wavelength of 1064 nm, respectively. The laser induced plasma radiation is transported by a fiber optic system onto the entrance slit of a monochromator (Jobin Yvon TRIAX 320). ICCD detector (Jobin Yvon Horiba) or a photomultiplier (Hamamatsu) gated by a laboratory built control unit are employed as detectors. For the gate time delay monitoring and time resolved signal recording, a digital storage oscilloscope Tektronix TDS 1012 is utilized. (en)
Title
  • Time resolved emission measurement in double-pulse LIBS
  • Time resolved emission measurement in double-pulse LIBS (en)
skos:prefLabel
  • Time resolved emission measurement in double-pulse LIBS
  • Time resolved emission measurement in double-pulse LIBS (en)
skos:notation
  • RIV/00216224:14310/08:00026271!RIV10-MSM-14310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM0021622411)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 400063
http://linked.open...ai/riv/idVysledku
  • RIV/00216224:14310/08:00026271
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • LIBS; time resolved emission measurement (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [69B401628F7B]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kaiser, Jozef
  • Kanický, Viktor
  • Malina, Radomír
  • Novotný, Karel
  • Otruba, Vítězslav
  • Galiová, Michaela
http://linked.open...n/vavai/riv/zamer
http://localhost/t...ganizacniJednotka
  • 14310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 107 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software