About: Effective Assessment of Diabetes Control Using Personal Glucometers (Contourlink, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA)     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Aim of this trial was to assess (1) the accuracy and precision of elektrochemistry-based glucometers CONTOURLINK, CALLA, and LINUS and (2) the diabetes control using Ambulatory Glycaemic Profiles (AGP) as markers of therapeutic effectiveness. Glucometers and COBAS INTEGRA 400 Plus analyzer were used by one laboratory professional to estimate P-glucose (PG) in 112 out-patients. There were 112 sets of 12 PG estimations analyzed. In each set, means of 3 capillary PG estimations on 3 respective glucometers and on INTEGRA analyzer were calculated. The statistical program SPSS, v. 15, was applied. The mean INTEGRA PG values ranged from 2.7 to 25.3 mmol/l. There were strong correlations between mean PG on INTEGRA versus CONTOURLINK, versus CALLA, and versus LINUS; PG deviations from INTEGRA were mostly within the range +-15%. Wilcoxon Signed Rank Test revealed differences between CONTOURLINK-INTEGRA and LINUS-INTEGRA; CALLA-INTEGRA showed no difference SD INTEGRA = 0.061 mmol/l, SD CONTOURLINK/SD CALLA/SD LINUS were 0.256/0.290/0.286 mmol/l. All patients were trained to perform defined 10-point PG profiles to adapt food, exercise, and insulin doses. The PG differences between all tested glucometers and reference values were borderline of ISO 15197 but worthy of consideration. AGP are felpful markers of diabetes control.
  • Aim of this trial was to assess (1) the accuracy and precision of elektrochemistry-based glucometers CONTOURLINK, CALLA, and LINUS and (2) the diabetes control using Ambulatory Glycaemic Profiles (AGP) as markers of therapeutic effectiveness. Glucometers and COBAS INTEGRA 400 Plus analyzer were used by one laboratory professional to estimate P-glucose (PG) in 112 out-patients. There were 112 sets of 12 PG estimations analyzed. In each set, means of 3 capillary PG estimations on 3 respective glucometers and on INTEGRA analyzer were calculated. The statistical program SPSS, v. 15, was applied. The mean INTEGRA PG values ranged from 2.7 to 25.3 mmol/l. There were strong correlations between mean PG on INTEGRA versus CONTOURLINK, versus CALLA, and versus LINUS; PG deviations from INTEGRA were mostly within the range +-15%. Wilcoxon Signed Rank Test revealed differences between CONTOURLINK-INTEGRA and LINUS-INTEGRA; CALLA-INTEGRA showed no difference SD INTEGRA = 0.061 mmol/l, SD CONTOURLINK/SD CALLA/SD LINUS were 0.256/0.290/0.286 mmol/l. All patients were trained to perform defined 10-point PG profiles to adapt food, exercise, and insulin doses. The PG differences between all tested glucometers and reference values were borderline of ISO 15197 but worthy of consideration. AGP are felpful markers of diabetes control. (en)
Title
  • Effective Assessment of Diabetes Control Using Personal Glucometers (Contourlink, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA)
  • Effective Assessment of Diabetes Control Using Personal Glucometers (Contourlink, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA) (en)
skos:prefLabel
  • Effective Assessment of Diabetes Control Using Personal Glucometers (Contourlink, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA)
  • Effective Assessment of Diabetes Control Using Personal Glucometers (Contourlink, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA) (en)
skos:notation
  • RIV/61989592:15110/13:33145914!RIV14-MSM-15110___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...iv/cisloPeriodika
  • 6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 71851
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15110/13:33145914
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • USA; Agamatrix; LINUS; Austria; Wellion; CALLA; Germany; Bayer; Contourlink; Glucometers; Personal; Using; Control; Diabetes; Assessment; Effective (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [872831B28DB1]
http://linked.open...i/riv/nazevZdroje
  • Disease Markers
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 35
http://linked.open...iv/tvurceVysledku
  • Krystyník, Ondřej
  • Procházka, Vlastimil
  • Zapletalová, Jana
  • Chlup, Rudolf
  • Bartek, Josef
  • Doubravová, B.
issn
  • 1875-8630
number of pages
http://localhost/t...ganizacniJednotka
  • 15110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 32 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software