Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - Suggested project deals with possibilities of the formation of MS/MS libraries using soft ionization techniques. The negative-ion electrospray ionization will be used for anionic dyes studied. The formation of MS/MS libraries for soft ionization techniques is quite rare except for biomolecules due to the limited transferability of results among various mass analyzers. Therefore, the first goal of the project is a definition of the standard measurement conditions allowing the comparison of measured spectra among the ion traps from different manufacturers. The acquired results will be also compared with MS/MS spectra measured on different types of mass analyzers (e.g. triple quadrupole) with the aim to determine the differences and the level of results transferability among various mass analyzers. Three different collision energies will be applied for MS/MS measurements on the ion trap to improve the comparison with the results measured on the triple quadrupole, where the higher (en)
- Navrhovaný projekt se zabývá studiem možností tvorby knihoven MS/MS spekter s použitím šetrných ionizačních technik. Pro studovaná anionická barviva bude použita ionizace elektrosprejem při záznamu záporných iontů. Tvorba MS/MS knihoven s využitím šetrných ionizačních technik se kromě biomolekul doposud používá zřídka kvůli omezené přenositelnosti výsledků mezi různými typy analyzátorů, a proto prvním cílem projektu bude snaha o nalezení standardních podmínek měření, ze kterých by naměřená spektrabyla srovnatelná pro iontové pasti různých výrobců. Získané výsledky budou porovnány i s MS/MS spektry změřenými na jiných typech hmotnostních analyzátorů (např. trojitý kvadrupólový analyzátor, lineární iontová past) a určeny rozdíly a stupeň převoditelnosti výsledků mezi různými typy analyzátorů. Spektra budou měřena při třech různých kolizních energiích kvůli zlepšení možnosti porovnání s výsledky měřenými na trojitém kvadrupólu, kde lze očekávat vyšší intenzitu fragmentových iontů s
|
Title
| - Tandem mass spectral libraries of anionic dyes (en)
- Knihovny tandemových hmotnostních spekter anionických barviv
|
skos:notation
| |
http://linked.open...avai/cep/aktivita
| |
http://linked.open...kovaStatniPodpora
| |
http://linked.open...ep/celkoveNaklady
| |
http://linked.open...datumDodatniDoRIV
| |
http://linked.open...i/cep/druhSouteze
| |
http://linked.open...ep/duvernostUdaju
| |
http://linked.open.../cep/fazeProjektu
| |
http://linked.open...ai/cep/hlavniObor
| |
http://linked.open...hodnoceniProjektu
| |
http://linked.open...vai/cep/kategorie
| |
http://linked.open.../cep/klicovaSlova
| |
http://linked.open...ep/partnetrHlavni
| |
http://linked.open...inujicichPrijemcu
| |
http://linked.open...cep/pocetPrijemcu
| |
http://linked.open...ocetSpoluPrijemcu
| |
http://linked.open.../pocetVysledkuRIV
| |
http://linked.open...enychVysledkuVRIV
| |
http://linked.open...okUkonceniPodpory
| |
http://linked.open...okZahajeniPodpory
| |
http://linked.open...iciPoslednihoRoku
| |
http://linked.open...atUdajeProjZameru
| |
http://linked.open.../vavai/cep/soutez
| |
http://linked.open...usZobrazovaneFaze
| |
http://linked.open...ai/cep/typPojektu
| |
http://linked.open...jektu+dodavatelem
| - The work on this grant project has resulted in 5 articles in renowned international journals and 9 contributions at international conferences, 2 other articles are in progress. Tandem mass spectra of several hundreds of organic dyes, intermediates, degra (en)
- V rámci řešení grantového projektu bylo publikováno 5 článků v renomovaných mezinárodních časopisech a prezentováno 9 příspěvků na mezinárodních konferencích, 2 další články jsou v řízení. V průběhu řešení projektu byla změřena a zinterpretována tandemov (cs)
|
http://linked.open...tniCyklusProjektu
| |
is http://linked.open...vavai/cep/projekt
of | |