About: Bone bed of loaded dental implant - comparison of in vivo status and 3D model     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The substantial body of evidence in the literature suggests, that the stress distribution around loaded dental implants reaches maximum by the cervical bone crest and at the apical-most part of the implant. Clinical evaluations denote, that most of implants unbinds from the bone in the cervical area from 0,1 to 0,5 mm per a year. The magnitude and distribution of maximal stress depend mainly on the implant shape and its surface arrangement. Designed study will evaluate dental intraosseal implants having been functionally loaded at last one year. Changes of the implant bone bed will be evaluated in a six month period employing the RVG imaging. The level of bone bed crest and the bone density at the apical and the cervical part of the implant will be checked. These in vivo recorded changes will be compared with an appropriate mathematical 3D model of stress distribution computed by a finite element analysis method. The correspondence of in vivo findings with those of mathematical modelling will be (en)
  • Z literatury je známo, že u implantátů je při zatížení žvýkací silou maximální napětí v oblasti krčku, popřípadě na apikálním konci implantátu. Klinické hodnocení udává úbytek kosti v krčkové partii kolem 0,1 - 0,5 mm za rok. Ukazuje se, že velikost a rozložení maximálního napětí závisí na tvaru implantátu a jeho povrchové úpravě. Navrhovaná studie bude sledovat nitrokostní dentální implantáty, které jsou minimálně 1 rok po zařazení do funkce. Metodou radiovisiografie bude hodnotit změny kostního lůžkimplantátů v intervalech šest měsíců, a to jak úroveň okraje kostního lůžka, tak i denzitu kosti v oblasti krčku a apikálního konce implantátu. Tyto in vivo změny budou porovnány s příslušným matematickým 3D modelem rozložení napětí vypracovaným metodou konečných prvků a bude zhodnoceno, do jaké míry odpovídá modelová situace stavu in vivo. Získané údaje budou použity pro přizpůsobení matematického 3D modelu podmínkám in vivo, aby lépe kopíroval podmínky v praxi.
Title
  • Bone bed of loaded dental implant - comparison of in vivo status and 3D model (en)
  • Porovnání stavu kostního lůžka zatíženého dentálního implantátu in vivo a jeho 3D modelu
skos:notation
  • GA304/00/P048
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open.../cep/klicovaSlova
  • Neuvedeno. (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open.../cep/vedlejsiObor
http://linked.open...jektu+dodavatelem
  • Cíle projektu byly splněny a jsou v souladu se zadáním. Bylo dosaženo pozoruhodných výsledků v matematickém modelování biomechanických faktorů zubních implantátů. Výsledky budou použitelné v klinické praxi. Jedna zahraniční publikace v tisku /J.Prost. De (cs)
http://linked.open...tniCyklusProjektu
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 89 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software